5
3. Slide the coil assembly out using the bottom drain pan to
pull the assembly from the cabinet.
4. For flipping the coil, drain pan extension must be removed
for all models except AVPEC61D14. Center support should
not be removed while removing the drain pan extension.
Side drain pan and horizontal drip shield can be removed for
downflow application. The side drain pan and horizontal drip
shield cannot be removed for horizontal right.
Figure 2-1
WIRE TIE LOCATION TO BE SECURED
Figure 2-2
WIRE TIE LOCATION TO BE REMOVED
.59
(15 mm )
1.57
(40 mm )
2.36
(60 mm )
.59
15 mm)
Wire tie
Wire tie
Screw
2
1
3
4
Detail D
Detail C
D
C
5
Center
Support
Corner
Post
*Do not get the
trap to touch
the coil tubing
Bundle excess
wire and secure
it to the corner
post using screw mount
wire ties
(3) Secure the insulated connectors to
the corner using two screws and the
mounting wire ties provided.
(2) Connect the junction connectors
and slide the insulation over it.
Secure the insulation on the
junction using two wire ties.
(1) Insert the junction-
connectors into the
insulation
Junction wires
Insulation
Insulation
Sensor wires
Screw
mount
wire tie
Screw
mount
wire tie
Screw
mount
wire tie
(Front view)
(Side view)
Screw
(Front view)
(Side view)
5. Using the bottom drain pan to hold the coil assembly, slide
the coil assembly back into the cabinet on the downflow
brackets as shown in Figure 9.