PRODUCT DIMENSIONS

*CSS96

A

34‰

11

14

25

28

C

11

14

14

25

3‰

 2‰

2

23

14

1‰

E

UNFOLDED

FLANGES

D

FOLDED FLANGES

18

FOLDED FLANGES

20

UNFOLDED FLANGS

 1

2‰

6‰

2

AIR

DISCHARGE

SIDE CUT-OUT

SIDE CUT-OUT

AIR

DISCHARGE

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

LOW VOLTAGE
ELECTRICAL OUTLET

ALTERNATE  GAS
SUPPLY LOCATION

HIGH VOLTAGE
ELECTRICAL 
OUTLET

STANDARD DRAIN TRAP

CONNECTION

 PVC

LEFT SIDE EXTERIOR

DRAIN TRAP HOLES

ALTERNATE 

GAS SUPPLY 

LOCATION

ALTERNATE VENT/
FLUE LOCATION

HIGH VOLTAGE

ELECTRICAL 

OUTLET

RIGHT SIDE EXTERIOR

DRAIN TRAP HOLES

LOW VOLTAGE

ELECTRICAL

OUTLET

RIGHT SIDE VIEW

TOP VIEW

FRONT VIEW

C = If placed on combustible floor, the floor MUST be wood ONLY.
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

Hori zonta l

6"

0"

3"

C

0"

6"

Position

Sides

Rear

Front

Bottom

Flue

Top

Downfl ow

0"

0"

3"

NC

0"

1"

M

INIMUM

 C

LEARANCES

 

TO

 C

OMBUSTIBLE

 M

ATERIAL

Model

A

B

C

D

E

*CSS960402BN**

17-1/2"

14-5/8"

14"

14-1/2"

16"

*CSS960603BN**

17-1/2"

14-5/8"

14"

14-1/2"

16"

*CSS960804CN**

21"

18-1/8"

17-1/2"

18"

19-1/2"

*CSS961005CN**

21"

18-1/8"

17-1/2"

18"

19-1/2"

*CSS961205DN**

24-1/2"

21-5/8"

21"

21-1/2"

23"

Summary of Contents for *CSS96 Series

Page 1: ...PEED GAS FURNACE UP TO 96 AFUE Refer to Service Manual RS6612012 for installation operation and troubleshooting information All safety information must be followed as provided in the Service Manual Re...

Page 2: ...h nician at a minimum as specified by the Air Conditioning Heating and Refrigeration Institute AHRI Attempting to install or repair this unit without such background may result in product damage perso...

Page 3: ...ARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditi...

Page 4: ...RICAL OUTLET STANDARD GAS SUPPLY LOCATION CENTER DIMPLE FOR ALTERNATE AIR INTAKE PIPE 3 OD HOLE AIR INTAKE 2 PIPE LEFT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOLTAGE ELECTRICAL OUTLET LOW VOLTAGE ELECTRI...

Page 5: ...HIGH VOLTAGE ELECTRICAL OUTLET RIGHT SIDE EXTERIOR DRAIN TRAP HOLES LOW VOLTAGE ELECTRICAL OUTLET RIGHT SIDE VIEW TOP VIEW FRONT VIEW C If placed on combustible floor the floor MUST be wood ONLY NC Fo...

Page 6: ...683 853 853 948 1 024 Disposable 213 256 341 427 427 474 512 Electrical Data Min Circuit Ampacity 9 6 9 6 12 8 12 8 13 7 13 7 13 7 15 15 15 15 15 15 15 Shipping Weight lbs N A Natural Gas BTU h Vent...

Page 7: ...clearance must take precedence over clearances from the enclosure where accessibility clearances are greater CSS96 0402BNA CSS96 0603BNA CSS96 0804CNA CSS96 1005CNA CSS96 1205DNA High Fire Input 40 00...

Page 8: ...620 N A 620 N A 610 N A 604 571 519 HIGH 5 0 2233 32 2159 33 2086 34 2024 35 1941 37 1850 1753 1651 MED 4 0 1820 39 1778 40 1742 41 1695 42 1638 43 1551 1485 1384 MED LO 3 5 1571 45 1535 46 1497 48 14...

Page 9: ...ALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH 9 Wiring is subject to change Always refer to the wiring diagram on the unit...

Reviews: