background image

11

OPERATION

(CONT'D)

OPTIONAL DIGITAL CONTROL

Note:

All controls are low voltage. 18 to 24 gauge wire is recommended.

FILTER LIGHT RESET & MODE FAN
SPEED SELECTOR

Press to reset the filter mainte-
nance reminder light. The combi-
nation filter light reset and up
setpoint selector buttons    let’s
you choose at which speed the
HRV, ERV unit will operate in
continuous or recirculation mode
only. Pressing the filter light
reset button once displays the
mode fan speed on the LCD. The
LCD should display one of the
following three letters, L for
Low, M for Medium and H for
High. To change the mode
speed, press the up setpoint
until desired speed is displayed,
selector. After 1 second of inac-
tivity, the LCD will return to rel-
ative humidity reading.

OVERRIDE TIMER

When pressed, unit will 
provide high speed 
ventilation for 15 minute
period. Once the time
elapsed the unit will return
to its normal function. To
move from one time to the
other, continue pressing the
timer button until you reach
the desired time.

DIGITAL DISPLAY 

Shows Indoor Humidity Level
This control will not read below
29% RH

DEHUMIDISTAT CONTROL

A Dehumidistat is ideal for use in energy efficient houses where
indoor humidity (during the heating season) is higher than outdoor
levels. High humidity is a major cause of structure damage and IAQ
problems such as mold and mildew.

MAINTENANCE LIGHT

Light comes on when it’s time
to clean unit. This function will
let you know when it's time to
check your filters and core. To
reset your filter light, after
you've cleaned or replaced the
filters, just push the power but-
ton and restart the unit. This
will turn the light off and reset
the clock for your filter check.

POWER

On/Off and Reset
This function is to turn your
unit on or off, in the off posi-
tion the damper is open and
you will feel the cold outside
air come in. To go from the
on to off position just press
once.

MODES

Select Intermittent, or
Continuous Ventilation Modes.

Continuous

This function will exchange
outside air with your stale

air.

Intermittent

This function will put your
unit on stand by and can

be over ride by timer, air quality
sensor, etc

To move from function to the
other, continue pressing the
mode button until you reach the
desired function. This function
goes from Recirculation,
Continuous to Intermittent.

DEHUMIDISTAT CONTROL

The LCD (Liquid Crystal Display) indicates the percentage of Relative
Humidity in the air surrounding the control and ultimately in the
house. Pressing either of the setpoint selectors (     ,     ) once, will
display the desired RH level. The setpoint selection mode is now acti-
vated and can be adjusted with either selectors to a newly desired
setpoint. The LCD will return to the actual RH level display after a few
seconds.

DMFC 

DIGITAL MULTI-FUNCTION
WALL CONTROL

Control multiple functions of
your HRV with one slimline
wall control. Two wire connec-
tion simplifies installation.
Use one control per HRV
installed.

Summary of Contents for HRV-150

Page 1: ...urnace or air handler operating at a higher static After installation the compatibility of the two pieces of equipment must be confirmed by measuring the airflow s of the Heat Recovery or Energy Recovery Ventilators by using the balancing procedure found in this manual It is always important to assess how the operation of any HRV ERV may interact with vented combustion equipment i e Gas Furnaces O...

Page 2: ...ht of the ceiling to get cubic volume Then divide by 60 and multiply by 0 35 Example SQFT of House 1100 Basement 1100 Total SQFT 2200 Height of ceiling x 8 Cubic volume 17600 60 Maximum airflow required CFM 293 x 0 35 103 Always consult your local code for sizing requirements in your area Room classification Number of rooms CFM L s CFM Required Master bedroom x 20 cfm 10 l s Basement yes or no Bed...

Page 3: ... maintenance free operation Seven 7 year limited warranty CORE Aluminum heat recovery core configured for an efficient cross flow ventilation Core is 9 x 9 229 x 229 mm with a 15 380 mm depth HRV 150D or 12 x 12 305 x 305 mm with a 15 380 mm depth HRV 200D Cores are manufactured to withstand extreme temperature variations FILTERS Two 2 Washable Electrostatic Panel Type Air Filters HRV 150D is 8 5 ...

Page 4: ...Air From Inside 5TH port for recirculation defrost models only can be ducted or left open Airflow HRV 150D HRV 200D Model A B C D E HRV 150D 2 56mm 23 596mm 2 67mm 17 441mm 17 441mm HRV 200D 2 56mm 27 707mm 2 67mm 17 441mm 20 520mm Fan Performance Performance Data Model HRV 150D 72 69 HRV 200D 71 76 Apparent Sensible Effectiveness at 32ºF 0ºC Apparent Sensible Effectiveness at 13ºF 25ºC AIRFLOW CA...

Page 5: ...y lubricated sealed bearings guarantee long life and maintenance free operation Seven 7 year limited limited warranty CORE Aluminum heat recovery core configured for an efficient cross flow ventilation Core is 9 x 9 229 x 229 mm with a 15 380 mm depth HRV 150 or 12 x 12 305 x 305 mm with a 15 380 mm depth HRV 200 Cores are manufactured to withstand extreme temperature variations FILTERS Two 2 Wash...

Page 6: ...side Stale Air From Inside Airflow Model A B C D E HRV 150 2 56mm 23 596mm 2 67mm 17 441mm 16 413mm HRV 200 2 56mm 27 707mm 2 67mm 17 441mm 20 520mm Fan Performance Performance Data 6 Model HRV 150 72 69 HRV 200 71 76 Apparent Sensible Effectiveness at 32ºF 0ºC Apparent Sensible Effectiveness at 13ºF 25ºC AIRFLOW CAP cfm L s 0 4 on High Speed Power Volts 120 VAC Amperage HRV 150 1 5 Amps Total HRV...

Page 7: ...enance free operation Seven 7 year limited warranty CORES Two 2 aluminum heat recovery cores configured for an efficient cross flow ventilation Core is 12 x 12 305 x 305 mm with a 15 380 mm depth Cores are manufactured to withstand extreme temperature variations FILTERS Two 2 synthetic high quality filters for better indoor air quality and clean air CONTROLS External three 3 position Low Stand By ...

Page 8: ...re in WC Static Pressure Pa 200 00 240 00 280 00 320 00 360 00 19 00 0 00 38 00 57 00 76 00 94 00 114 00 123 00 142 00 162 00 5TH port for recirculation defrost models only can be ducted or left open Airflow Performance Data Model HRV 300D 92 91 Apparent Sensible Effectiveness at 32ºF 0ºC Apparent Sensible Effectiveness at 13ºF 25ºC AIRFLOW CAP cfm L s 0 4 on High Speed Power Volts 120 VAC Amperag...

Page 9: ...tal control An on board diagnostic LED helps find problems quickly and efficiently For example the LED can be used to signal a broken or shorted electronic wall control wire Electronic air temperature probe gives this board accurate readings in order to minimize unnecessary defrost operation and the on board jumpers provide the user with the option of adjusting defrost time and sequence to optimiz...

Page 10: ... higher than outdoor levels High humidity is a major cause of structure damage and IAQ problems such as mold and mildew 2 wire installation 4 wire installation 3 wire installation 2 wire installation DMFC REC DIGITAL MULTI FUNCTION WALL CONTROL WITH RECIRCULATION Control multiple functions of your HRV with one slimline wall control Two wire connec tion simplifies installation Use one control per H...

Page 11: ...ht comes on when it s time to clean unit This function will let you know when it s time to check your filters and core To reset your filter light after you ve cleaned or replaced the filters just push the power but ton and restart the unit This will turn the light off and reset the clock for your filter check POWER On Off and Reset This function is to turn your unit on or off in the off posi tion ...

Page 12: ...g its defrost mode the HRV may produce some condensation This water should flow into a nearby drain or be taken away by a condensate pump The HRV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point A P trap should be made in the drain line This will prevent odors from being drawn back up into the unit MOUNTING LOCATION The HRV must be ...

Page 13: ...barrier must be completely sealed to outer wall and the HRV using tape and or caulking A good bead of high quality caulk ing preferably acoustical sealant will seal the inner flexible duct to both the HRV port and the weatherhood prior to clamping To minimize air flow restriction the flexible insulated duct that connects the two outside weatherhoods to the HRV should be stretched tightly and be as...

Page 14: ... elbows as possible Forty five degree are preferred to 90º elbows Use Y tees instead of 90º elbows whenever possible All duct joints must be fastened with screws or duct sealant and wrapped with a quality duct tape to prevent leakage Aluminum foil duct tape is recommended Galvanized ducting from the HRV to the living areas in the house is recommended whenever possible although flexible duct can be...

Page 15: ...rilles be completely opened at first and then adjusted later as needed Dedicated Installation for Existing Home non forced air heating cooling system 1 Begin with the duct collar marked Exhaust Air In Slide a short piece 12 of flexible duct over the duct collar Using duct tape tape the flexible duct to the collar Run the flexible ducting to the main rigid duct trunk line which connects to the rema...

Page 16: ... EXAMPLES Example diagram only duct configuration may change depending on model It is the responsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform as intended All air movement devices have a performance curve The amount of air CFM that an HRV ERV will deliver is directly related to the total external static pressure E S P of the sy...

Page 17: ...from key areas of home Exhaust Air from various parts of home i e bathrooms if required kitchens if required NOTES 1 Furnace blower may be required to operate when HRV ERV is on to provide good air distribution 2 Weatherhood arrangement is for drawing purposes only 6 2m minimum separation recommended 18 460mm above grade minimum 3 Due to the differences in pressure between the HRV ERV and the equi...

Page 18: ...ously or interlocked with HRV ERV 2 A minimum separation of 39 inches 1m is recommended between the two direct connections 3 The exhaust air connection should be upstream of the supply air connection to prevent exhausting any fresh air 4 Weatherhood arrangement is for drawing purposes only 6 2m minimum separation recommended 18 460 mm above grade minimum 5 Due to the differences in pressure betwee...

Page 19: ...nace should be set to run continuously or interlocked with HRV ERV 2 The exhaust air connection should be upstream of the supply air connection to prevent exhausting any fresh air 3 Weatherhood arrangement is for drawing purposes only Six feet 2m minimum separation recommended Eighteen inches 460 mm above grade minimum 4 Due to the differences in pressure between the HRV ERV and the equipment it i...

Page 20: ...allation may limit the amount of straight duct The Pitot tube should be connected to a magnehelic gauge or other manometer capable of reading from 0 to 0 25 in 0 62 Pa of water preferably to 3 digits of resolution The tube coming out of the top of the pitot is connected to the high pressure side of the gauge The tube com ing out of the side of the pitot is connected to the low pressure or ref eren...

Page 21: ...vious steps to adjust the Exhaust Air Out damper if needed B Measure here Measure here 18 457 mm 18 457 mm To avoid airflow turbulence and incorrect readings the airflow velocity should be measured on steel ducting a minimum of 18 457 mm from the unit or elbow and before any transition ELECTRONIC BALANCING MOTORS HRV 150D 200D only Motors will be factory set at their full potential depending on sp...

Page 22: ...oing any repairs or mainte nance a Open access door b Carefully grip ends of core and pull evenly out ward Core may be snug but will slide out of the channel c Once removed from the cabinet remove filters d Wash core in warm soapy water do not use dishwasher e Install the clean filters f Install clean core To Install the Clean Core and Filters a First mount the bottom flange of the core guide into...

Page 23: ...V ERV Locate the grilles high on the walls or under the baseboards install ceiling mounted diffuser or grilles so as not to directly spill the supply air on the occupant eg Over a sofa Turn down the HRV ERV supply speed A small duct heater 1kw could be used to temper the supply air Placement of furniture or closed doors is restricting the movement of air in the home If supply air is ducted into fu...

Page 24: ... COOLING SYSTEM WIRE JOINT DMFC REC This control is not polarity sensitive therefore you may connect any wire to either positive or negative connection DMFC REC or DMFC RT 15M MD 2W or CT 30M MD 4W DMFC This control is not polarity sensitive therefore you may connect any wire to either positive or negative connection 2 wire connection RT 15M Connect to positive and negative connections on elec tri...

Page 25: ...ELECTRICAL CONNECTIONS CONT D Custom defrost mode jumper selection 3 position mode selection switch Accessory Control Contact Open Closes contact when HRV ERV is ON OFF Diagnostic LED U Air Quality Sensor ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ...ns components and specifications Item 402950 Rev 1 Rev Date 11022006 United States 1712 Northgate Blvd Sarasota FL 34234 Phone 800 747 1762 941 309 6000 Fax 800 487 9915 941 309 6099 www fantech net info fantech net Canada 50 Kanalflakt Way Bouctouche NB E4S 3M5 Phone 800 565 3548 506 743 9500 Fax 877 747 8116 506 743 9600 www fantech ca info fantech ca ...

Reviews: