POWER SUPPLY WIRE SPECIFICATIONS
120Volt, 60Hz, 1500 Watts:
Hard Wire Connection – Use two conductor, non-metallic sheath cable with
ground wire (total three wires) for the incoming power supply. The wire used
must conform to local and national electrical codes for the specified power
consumption rating. See Table 1.
240Volt, 50-60Hz, 3000 Watts:
Hard Wire Connection – Use three conductor, non-metallic sheath cable with
ground wire (total four wires) for the incoming power supply. The wire used
must conform to local and national electrical codes for the specified power
consumption rating. See Table 1.
Power Supply Wire Gage
Voltage
Wire Gage
Fuse
120 V
14 GA.
15 AMP
240 V
14 GA.
20 AMP
Table 1
Consult with professional electrician and adhere to all code requirements for
installations in bathrooms
FOR BATHROOM USE
If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit. If
receptacle is used it must be readily accessible.
To prevent electric shock, please be aware that this unit is an electrical appliance that is
NOT
watertight and must be installed as to prevent water from entering unit. This must be
installed away from shows, tubs, etc. Never locate fireplace where it may fall into a bathtub
or other water container.
All wiring connections to line power shall be in accordance with local building code
requirements. Inquires about local codes and regulations must be done prior to installation.
(ref. Page 19)