background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNPACKING AND TESTING APPLIANCE 

 

Carefully remove the appliance from the box. 

 

Prior to installing the appliance, test to make sure the appliance operates properly by plugging the 
power supply cord into a conveniently located 120 Volt grounded outlet. 

 

Test all aspects of its operation (manual switches, remote and heater) to make sure all components 
operate correctly. 

 

As  with  most  electronic  devices,  your  new  electric  fireplace  has  been  designed  to  operate  at 
temperatures  between  5 

 

(41

)  and  3

 

(95

).  During  the  cold  winter  months,  allow  the

 

fireplace to reach room temperature before turning it on. 

 

NOTE:  There  may  be  trace  of  odor  during  the  first  few  minutes  of  initial  use.  This  is  harmless, 
normal and will never occur again. 

 
 

 

 

GROUNDING APPLIANCE 

 

This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C) 
is  available  for  connecting  three-blade  grounding  type  plugs  to  two-slot  receptacles.  The  green 
grounding  lug  extending  from  the  adapter  must  be  connected  to  a  permanent  ground  such  as  a 
properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is 
available. 

 

To disconnect appliance, turn controls to off, then remove plug from outlet. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

LOCATING THE FIREPLACE 

 

Plan where to locate and frame the fireplace. This will save time and money later when you install 
the fireplace. Before installation consider the following: 

 

1.

 

Where the fireplace is located must allow for wall and ceiling clearances 

 
2.

 

Consider  a  location  where  the  fireplace  screen  will  not  be  exposed  to  direct  sunlight  from 
windows or doors. 

 

3.

 

A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location. 
Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses 
to blow.

 

 

5

Summary of Contents for 40-TRV-XL-XT

Page 1: ...N WARNING For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage Do not store or use gasoline or other flammable...

Page 2: ...IONS 11 SAFETY DRILL SCREW AREA 12 OUTDOOR INSTALLATION 12 INSTALLATION 13 HARDWIRE INSTALLATION 19 MEDIA OPTIONS 22 DECORATIVE MEDIA INSTALLATION 22 OPERATION 23 MANUAL OPERATION 23 REMOTE CONTROL OP...

Page 3: ...ea and where it will not be tripped over 7 Do not modify this fireplace Use it as described in the manual Any other use not recommended by the manufacture may cause fire shock or injury to persons 8 D...

Page 4: ...y energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a pa...

Page 5: ...a plug as shown in A An adapter as shown in C is available for connecting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected...

Page 6: ...m 33 837 2mm 395 8 1007mm 133 4 348mm 61 4 160mm 14 1 4 363mm 55 8 144mm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliance...

Page 7: ...33 837 2mm 495 8 1261mm 133 4 348mm 61 4 160mm 14 1 4 363mm 55 8 144mm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances...

Page 8: ...5 8 1515mm 631 4 1605 6mm 133 4 348mm 61 4 160mm 14 1 4 363mm 55 8 144mm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliance...

Page 9: ...4 1910 4mm 715 8 1819 8mm 133 4 348mm 61 4 160mm 15 1 2 393mm 55 8 144mm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliance...

Page 10: ...4 2316 8mm 875 8 2226 2mm 133 4 348mm 61 4 160mm 15 1 2 393mm 55 8 144mm This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room applianc...

Page 11: ...Gage Fuse 120 V 14 GA 15 AMP 240 V 14 GA 20 AMP Table 1 Consult with professional electrician and adhere to all code requirements for installations in bathrooms FOR BATHROOM USE If this unit is insta...

Page 12: ...in outdoor areas protected from direct water impingement In addition to maintaining the listed mantel and combustibles clearances a rain protection overhang factor of 1 2 shall be constructed to the f...

Page 13: ...34 72 TRV XL XT TV T190072 01 75 3 4 14 1 4 34 88 TRV XL XT TV T190088 01 93 3 4 14 1 4 34 W D H 13 INSTALLATION The TRV XL XT models are designed to be built in and allow for the finishing material d...

Page 14: ...and the wall studs To fix the bottom of the fireplace and the wall studs with the framing plates that you ve removed from left and right side of the fireplace at STEP 4 Plug in and check if the firepl...

Page 15: ...from front and right side take off the fending panel on the right 2 Unscrew 7screws on the right side that fix the fending bar and panel and then take off the fending bar and panel 3 After the fendin...

Page 16: ...To fix the bottom of the fireplace and the wall studs with the framing plates that you ve removed from left and right side of the fireplace at STEP 4 Plug in and check if the fireplace works 7 After c...

Page 17: ...rew 7 screws on the left side that fix the fending bar and panel and then take off the fending bar and panel 3 After the fending panel is removed screw back the bar 4 Remove the framing plates from th...

Page 18: ...and the wall studs with the framing plates that you ve removed from left and right side of the fireplace at STEP 4 Plug in and check if the fireplace works 7 After checking that the fireplace operates...

Page 19: ...ure the live wire goes into the L the neutral wire into N and the ground wire into G Return the cover plate to the left side and screw the two screws back in to fasten the Turn off the appliance compl...

Page 20: ...NG ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION L1 BLACK POWER L2 ORANGE POWER G GREEN GROUND N WHITE COMMON N1 BLUE COMMON N2 BLUE COMMON 2 2 WIRING See Power Supply Specifications on...

Page 21: ...ORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION L1 BLACK POWER L2 ORANGE POWER G GREEN GROUND N WHITE COMMON N1 BLUE COMMON N2 BLUE COMMON 3 2 WIRING See Power Supply Specifications on Page 1...

Page 22: ...wobracketswhich arefendingthefrontglasspanel Screwsandbrackets 2 Afterthebracketsareremoved thefrontglasspanel willfalldownautomatically 4 Installing the fire glass media Pour the fire glass media int...

Page 23: ...ff time 30min 1h 2h 3h 4h 5h 6h 7h 8h t0 The indicator light turns off automatically leaving it not operated within 10 seconds The timing turns off when is pressed 5 Press to turn on and off the heate...

Page 24: ...o confirm day of the week and then enter hour setting Press or to set the hour press to confirm the hour and then enter minute setting Press or to set the minute and press to confirm the minute and fi...

Page 25: ...LCD screen of the remote control shows 6 6 6 Press or or to change the brightness of each color flame 7 Day Timer Function Press once 7 days from Monday to Sunday will display on the LCD screen of the...

Page 26: ...da will disappears NOTE If the 7 day timing and the general timing are set at the same time the system will respond to an earlier shutdown time Press Refer button to check the settings of 7 day timer...

Page 27: ...one download and install 2 Scan the QR code below with your mobile phone WIFI SETTING AND FIREPLACE OPERATION 1 Create an account and log in 2 When you log in touch FIG 1 to enter in FIG 2 Touch other...

Page 28: ...om the fireplace and the flame button will flash as well indicating that Wi fi is in EZ mode Then please confirm to go next FIG 5 4 The APP will scan FIG 6 and add the fireplace to APP FIG 7 automatic...

Page 29: ...29 6 Now you are in the interface like FIG 7 You can operate the fireplace via Wi fi FIG 7...

Page 30: ...44 Qty 12 601144 Qty 8 8 Flicker Assembly 2 3151505B 3123505B 3124505B 3125505B 3235505 9 Flame Motor 2 1010501 1010501 1010501 1010501 1010501 10 Touch Panel 1 10124003 10124003 10124003 10124003 101...

Page 31: ...EXPLODED VIEW 31...

Page 32: ...Wiring Diagram 32...

Page 33: ...gged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 min...

Page 34: ...SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES 34...

Page 35: ...35...

Reviews: