1.  Take out the unit from the box. Please do the pre

Pull out the optional trim from the unit as shows below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 
2.  Remove the framing plates from the unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Take out the unit from the box. Please do the pre-test before you install the fireplace

ull out the optional trim from the unit as shows below. 

plates from the unit. 

test before you install the fireplace. 

optional trim

framing plate

Summary of Contents for BI-40-DEEP-XT

Page 1: ... MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE Version 202106 INSTALLATION OWNER S MANUAL PANORAMA BUILT IN DEEP XT SERIES DE T190040 01 DE T190050 01 DE T190060 01 DE T190072 01 DE T190088 01 ...

Page 2: ...RE SPECIFICATIONS 11 SAFETY DRILL SCREW AREA 12 OUTDOOR INSTALLATION 12 INSTALLATION 13 HARDWIRE INSTALLATION 19 MEDIA OPTIONS 22 DECORATIVE MEDIA INSTALLATION 22 OPERATION 23 MANUAL OPERATION 23 REMOTE CONTROL OPERATION 24 WIFI OPERATION 27 REPLACEMENT PARTS 30 EXPLODED VIEW 31 TROUBLE SHOOTING 32 SERVICE HISTORY 33 WARRANTY 34 Please read and carefully follow all of the instruction found in this...

Page 3: ... area and where it will not be tripped over 7 Do not modify this fireplace Use it as described in the manual Any other use not recommended by the manufacture may cause fire shock or injury to persons 8 Do not use this heater with programmer timer separate remote control system or any other device that switches the heater on automatically since a fire risk exists if the heater is covered or positio...

Page 4: ...cy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to c...

Page 5: ...ing the cold winter months allow the fireplace to reach room temperature before turning it on of odor during the first few minutes of initial use This is normal and will never occur again This appliance is for use on 120 Volts The cord has a plug as shown in A An adapter as shown in C is available for connecting three blade grounding type plugs to two receptacles The green grounding lug extending ...

Page 6: ...pening Size 40 30 or 101 6 cm 76 2 cm BTU 5118 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local c...

Page 7: ...l Opening Size 50 30 or 127 cm 76 2 cm BTU 5118 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local ...

Page 8: ...Opening Size 60 30 or 152 4 cm 76 2 cm BTU 5118 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local ...

Page 9: ...pening Size 73 1 2 30 or 186 7 cm 76 2 cm BTU 5118 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of loc...

Page 10: ...pening Size 89 1 2 30 or 227 3 cm 76 2 cm BTU 5118 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of loc...

Page 11: ...Wire Gage Fuse 120 V 14 GA 15 AMP 240 V 14 GA 20 AMP Table 1 Consult with professional electrician and adhere to all code requirements for installations in bathrooms FOR BATHROOM USE If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit If receptacle is used it must be readily accessible To prevent electric shock please be aware that this unit is an electrical...

Page 12: ...n outdoor areas protected from direct water impingement In addition to maintaining the listed mantel and combustibles clearances a rain protection overhang factor of 1 2 shall be constructed to the front and to each side of the installed appliance See illustration below All wiring connections to line power shall be in accordance with local building code requirements Inquires about local codes and ...

Page 13: ...pliance with local and national codes and other applicable regulations Prior to installing test the appliance to make sure the appliance is fully operational by plugging the power supply cord into a 120 Volt grounded outlet The rough wall opening size of the fireplace NOTE Due to the many different materials used to build walls it is highly recommended builder before you install this appliance on ...

Page 14: ... unit as shows below 2 Remove the framing plates from the unit Take out the unit from the box Please do the pre test before you install the fireplace ull out the optional trim from the unit as shows below plates from the unit test before you install the fireplace optional trim framing plate ...

Page 15: ...15 4 Bend up the framing plates Bend up the framing plates framing plate 3 Re attach the framing plates as shown in the picture ...

Page 16: ...o the opening 6 Drive the mounting screws into the f Put the unit into the opening Drive the mounting screws into the framing plates on the unit and the wall studs raming plates on the unit and the wall studs framing plate ...

Page 17: ...with glazed tile wallpaper etc After checking that the fireplace operates properly cover the glass panel with protective plastic bag and install plywood or drywall IMPORTANT NOTE IF YOU WANT TO USE THE SUPPLIED SURROUN Decorate the plywood or drywall with glazed tile wallpaper etc After checking that the fireplace operates properly cover the glass panel with protective IMPORTANT NOTE IF YOU WANT T...

Page 18: ...18 9 Put back the trim that you ve removed from the unit at STEP 1 trim ...

Page 19: ...ion block Please make sure the live wire goes into the L the neutral wire into N and the ground wire into G Return the cover plate to the left side and screw the two screws back in to fasten the Turn off the appliance completely and let cool before servicing Only a qualified service Remove the cover plate from the left side of the appliance by removing the two screws junction block Please make sur...

Page 20: ...ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION L1 BLACK POWER L2 ORANGE POWER G GREEN GROUND N WHITE COMMON N1 BLUE COMMON N2 BLUE COMMON 2 2 WIRING See Power Supply Specifications on Page 14 IF THE APPLIANCE IS TO BE HARD WIRED IN THE POWER CORD MUST BE REMOVED SEE INSTRUCTION 1 ON PAGE 20 2 120V BI 50 60 72 88 DEEP XT DE T190050 60 72 88 01 only 20 N L1 G GROUND 120 VAC N L1 GROUND ...

Page 21: ...S CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION L1 BLACK POWER L2 ORANGE POWER G GREEN GROUND N WHITE COMMON N1 BLUE COMMON N2 BLUE COMMON 3 2 WIRING See Power Supply Specifications on Page 14 IF THE APPLIANCE IS TO BE HARD WIRED IN THE POWER CORD MUST BE REMOVED SEE INSTRUCTION 1 ON PAGE 20 3 240V BI 50 60 72 88 DEEP XT DE T190050 60 72 88 01 only 21 N L1 L2 G GROUND 120 VAC 120 VAC N L1 L...

Page 22: ...nscrew the screw to take off the bracket Turn around the bracket and insert it into the gap to hook and pull out the glass 3 Put back the front glass and screw back the bracket This unit does not come with media Optional media is available for purchase See Dealer for additional details 2 Install optional media according to personal preference ...

Page 23: ...rn off time 30min 1h 2h 3h 4h 5h 6h 7h 8h t0 The indicator light turns off automatically leaving it not operated within 10 seconds The timing turns off when is pressed 5 Press to turn on and off the heater in its AUTO mode The setting temperature switch through 59 61 63 64 66 68 70 72 73 75 77 79 81 83 in Fahrenheit or 15 16 17 18 19 20 21 22 23 24 25 26 27 28 in Celsius The temperature setting mo...

Page 24: ...ss to confirm day of the week and then enter hour setting Press or to set the hour press to confirm the hour and then enter minute setting Press or to set the minute and press to confirm the minute and finish time setting Press this Power button to turn on and off the fireplace Press this Timer button to set the time to turn off the fireplace The available settings range from 30 minutes to 8 hours...

Page 25: ...the LCD screen of the remote control shows 6 6 6 Press or or to change the brightness of each color flame 7 Day Timer Function Press once 7 days from Monday to Sunday will display on the LCD screen of the remote control press within 5 seconds to enter 7 day timer function When Sun flashes press or to select the day that you want to set press to confirm your setting Then ON will be display on the L...

Page 26: ... da will disappears NOTE If the 7 day timing and the general timing are set at the same time the system will respond to an earlier shutdown time Press Refer button to check the settings of 7 day timer Press or to see the settings of the day of the week and or the settings of the startup and shutdown time y timer and the icon ...

Page 27: ...hone download and install 2 Scan the QR code below with your mobile phone WIFI SETTING AND FIREPLACE OPERATION 1 Create an account and log in 2 When you log in touch FIG 1 to enter in FIG 2 Touch others on the left corner first and then choose Connector Wi fi to enter in FIG 3 to set your Wi fi account and password FIG 1 FIG 2 FIG 3 ...

Page 28: ...rom the fireplace and the flame button will flash as well indicating that Wi fi is in EZ mode Then please confirm to go next FIG 5 4 The APP will scan FIG 6 and add the fireplace to APP FIG 7 automatically Please make sure the Wi fi account and password you set are correct and Wi fi signal is good 5 Touch Done to finish Wi fi setting FIG 7 FIG 5 FIG 6 FIG 7 ...

Page 29: ...29 6 Now you are in the interface like FIG 7 You can operate the fireplace via Wi fi FIG 7 ...

Page 30: ...it 601139B 601139B Qty 1 601139B 601139B Qty 1 601140B 601140B Qty 2 601140B Qty 2 601140B 601140B Qty 4 9 Adjustable Foot 4 10203015 10203015 10203015 10203015 10203015 10 Back Glass 1 10701263B 10701265B 10701267B 10701269B 10701270B 11 Glass Bracket LH 1 3057012 3057012 3057012 3057012 3057012 12 Glass Bracket RH 1 3057013 3057013 3057013 3057013 3057013 13 Tray Glass 1 10702189B 10702191B 1070...

Page 31: ...31 EXPLODED VIEW ...

Page 32: ... fuse has blown Replace the fuse Appliance will not come on when switch is flipped to ON Appliance is not plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 minutes then turn on Circuit board is burnt out Inspect the circuit board and replace if neces...

Page 33: ...SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Special Concerns NOTES 33 ...

Page 34: ...34 ...