The overhang (A) must extend at least 1/2 the roof-line height (B).
Height is measured from the base of the fireplace.
For example: if the roof-line (B) is 8’ above the base of the fireplace,
the overhang (A) must be at least 4’.
OUTDOOR INSTALLATIONS
The BI-DEEP series electric fireplaces are suitable for installation in outdoor areas protected from direct
water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain
protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed
appliance. See illustration below. All wiring connections to line power shall be in accordance with local
building code requirements. Inquires about local codes and regulations must be done prior to
installation.
When installed in outdoor applications, it is recommended that the BI-DEEP models use the protective
PAN-COVER.