8
3.
A 15 ampere, 240 Volt, 50 Hz branch circuit with proper ground must be available at the location.
Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses
to blow.
CLEARANCES WHEN BUILT-IN
The fireplace may be placed within a framed enclosure that is level, dry and capable of supporting
the weight of the appliance and front glass. It may be placed directly on wood or a non-combustible
surface(not on linoleum or carpet). The minimum clearance from the top of the appliance to a
mantel (combustible or non-combustible) is 2” (50.8 mm). The sides and back must maintain
1”(25.4mm) clearance to any material. The top must maintain a 3/8” (10mm) clearance to any
material.