5
3.
A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location.
Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses
to blow.
CLEARANCES WHTN BUILT-IN
The fireplace may be placed within a framed enclosure that is level, dry and capable of supporting
the weight of the appliance and front glass. It may be placed directly on wood or a non-combustible
surface(not on linoleum or carpet). The minimum clearance from the top of the appliance to a
mantel (combustible or non-combustible) is 2
”
(50.8 mm). The sides and back must maintain
1
”
(25.4mm) clearance to any material. The top must maintain a 3/8
”
(10mm) clearance to any
material.
NOTE: The air vents must have a 1 inch gap between the wall and the glass surround to allow the heat
to vent, and it can't be covered with finishing materials like stone or trim. It must remain clear. Please
also note that air must circulate at the bottom as well so please don't seal the gap between fireplace
and the floor to prevent from overheating.