Tables
54
A BAH0040-9 01.19
9
Tables
9.1
Machine data table
Mode 1
Code
Activating functions of the control terminal
1
Activate all functions of the control terminal
2
Only activate the hectare counter of the control terminal
Mode 2
Code
Number of track marker sensors
0
Machine with 2 track marker sensors,
e.g. front tank seeding combination with 2 track
marker sensors (Fig. 56/1).
Fig. 56
1
Machine
with 1 track marker sensor
on hydraulic valve (Fig. 57/1)
Fig. 57
Machine
with 1 track marker sensor
on marker changeovers (Fig. 58/1)
Fig. 58
2 to 99
The tramline counter counts the field passes. When lifting the track marker,
e.g. when lifting the seed drill to turn at the end of the field, the tramline count
will be increased.
If the seed drill does not have a track marker sensor, enter a number
between 2 and 99. The number equals the time in seconds between lifting of
the seed drill to turn (standstill of the seed drill) and increasing the tramline
count. After the set time elapses, the tramline count is increased.
If there is a brief pause before reaching the set time, the tramline counter
does not continue to count.