NOTE
A maximum of 16 section switches can be activated.
7. In the
"Switch"
table, assign each section to a
switch.
NOTE
Multiple part-width sections can be actuated with the
same section switch. To do so, the part-width sections
must be assigned to the same section switch.
5.6.2 Configuring section control for fertiliser spreaders
Configuring the tact
In this menu, the on/off point delays for switching the
individual part-width sections are set.
NOTE
For ISOBUS implements, the configuration of the
on/off point delays is performed only through the
Universal Terminal.
For information on the configuration of on/off point
delays for non-ISOBUS implements, see page 227.
Enabling virtual section switches
NOTE
This function is not available for fertiliser spreaders.
5.6.3 Configuring section control for seed drills
Configuring the part-width sections
In this menu, the part-width sections can be configured.
NOTE
For ISOBUS implements, the configuration of the part-
width sections is performed only through the Universal
Terminal.
005424
005420
005428
005432
005415
F | Configuring the AMAPAD | Configuring an implement
MG5574-
EN
-II | B.1 | 25.10.2016
92