10.2.12 Cleaning the segment distributor head
INTERVAL
Every 10 operating hours
or
daily
NOTE
The segment distributor head must be kept free of
dust, deposits, and foreign objects.
Shorten the checking intervals under very dusty
conditions.
WARNING
Risk of chemical burns by dressing dust
Before working with hazardous materials,
put on the protective clothing
recommended by the manufacturer.
1.
Loosen the four knurled screws
1
.
2.
Remove the cover
2
.
3.
Clean the segment distributor head
3
using a
paint brush, hand brush or with compressed air.
4.
Clean the seed outlets and tramline segments
4
using a paint brush, hand brush or with
compressed air.
5.
Install the cover.
6.
Tighten the four knurled screws by hand.
CMS-I-00003133
10.2.13 Cleaning the conveyor section
INTERVAL
Every 10 operating hours
or
daily
The air drawn by the fan can contain fertiliser dust
or sand. These impurities can accumulate on the
CMS-T-00004448-F.1
CMS-T-00009834-A.1
10 | Repairing the implement
Maintaining the implement
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE