4.12 Cyclone separator
The cyclone separator
1
protects the fan and the
implement under very dusty working conditions. The
intake air
3
is rotated so strongly in the cyclone
separator that the impurities are carried to the outer
wall and escape through the opening
2
.
CMS-I-00002764
4.13 Metering system
4.13.1 Metering unit
1
Hopper tip
2
Metering roller
3
Metering unit housing cover
4
Metering unit housing
3
2
4
1
CMS-I-00005085
A metering unit is installed under each hopper tip.
The metering roller is electrically driven and can be
exchanged. The metered material falls into the sluice
or injector and is directed by the air current to the
distributor head and then on to the coulters. As soon
as the implement is raised when turning at the end
of a field, the electric motor switches off and the
metering roller comes to a halt.
CMS-T-00005099-B.1
CMS-T-00009772-A.1
CMS-T-00007213-A.1
4 | Product description
Cyclone separator
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
34