10.2.7 Checking the RoTeC furrow former
INTERVAL
Every 50 operating hours
or
weekly
1.
Remove the depth control disc or depth control
wheel.
2.
When the indicated measurement
A
on a
furrow former is smaller than 98 mm,
replace the furrow former.
3.
To replace the furrow former,
remove the bolt
2
and dispose of it.
4.
Replace the worn furrow former
1
.
5.
Install the a new bolt
2
. The bolts for the furrow
former are coated and may not be reused.
2
1
A
CMS-I-00004667
10.2.8 Checking the RoTeC cutting discs
INTERVAL
Every 50 operating hours
or
weekly
Version
Original disc diameter
Wear limit
RoTeC coulter
317 mm
289 mm
RoTeC pro coulter
402 mm
365 mm
CMS-T-00006374-A.1
CMS-T-00010382-A.1
10 | Repairing the implement
Maintaining the implement
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
125