Assembly and function
Citan BAG0014.4 09.14
47
Air tank
Fig. 16/...
(1) Air tank
(2) Drainage valve for condensation.
Fig. 16
5.3.1
Coupling the brake and supply lines
WARNING
Risk of contusions, cuts, dragging, catching or knocks from
incorrectly functioning brake system.
•
When coupling the brake and supply line, ensure that:
ο
The sealing rings of the hose couplings are clean.
ο
The sealing rings of the hose couplings form a proper seal.
•
Always replace damaged seals immediately.
•
Drain the air tank before the first journey each day.
•
Only move off with the machine connected when the pressure
gauge on the tractor shows 5.0 bar.
WARNING
Risk of contusions, cuts, dragging, catching or knocks from
unintentionally rolling machine with the operating brake re-
leased!
Always couple the hose coupling of the brake line (yellow) first, fol-
lowed by the hose coupling of the supply line (red).
The operating brake of the machine moves out of the brake position
immediately the red hose coupling has been coupled.