Adjustments
Citan BAG0014.4 09.14
81
8.5.1
Calibration test with Vario gearbox
1. Fill the seed hopper with seed (200 kg cor-
respondingly less for fine seeds at fine
seeds).
2. Take the seed collecting trays off the
transport retainer on the rear side of the
hopper.
3. Slide the seed collection tray (Fig. 63) into
the bracket and place one seed collecting
tray underneath every individual metering
unit.
Fig. 63
4. Slacken the star knob (Fig. 64/1) of the
gearbox setting lever.
5. Move the gearbox setting lever (Fig. 64/2)
to one of the following gearbox settings:
Sowing with:
gearbox position
•
Coarse metering wheel:
50
•
Medium metering wheel
50
•
Fine metering wheel
15
6. Tighten star knob (Fig. 64/1).
Fig. 64
7. Open the injector sluice (Fig. 65/1) on all
metering units.
Fig. 65
Warning!
Danger of squeezing
when opening and closing the injec-
tor sluice (Fig. 65/1)!
Hold the injector sluice only on the
strap (Fig. 65/2), danger of injury
when the sprung loaded injector
sluice flap shuts (Fig. 65/1).
Never ever reach with your hand
between the injector sluice flap (Fig.
65/1) and the injector sluice.