Settings
Primera BAG0175.3 07.18
107
8.1.2
Replacing the dosing roller
CAUTION
Switch off the control terminal!
Risk of accident due to unintended movements of the metering unit or
other implement components caused by radar pulses.
The metering roller can be replaced more easily if the hopper is
empty.
1. Take the wrench out of the holder on the
metering unit.
Fig. 81
2. Close the hopper opening with the shutter
(only necessary when the hopper is full).
Loosen two nuts but do not remove.
Swivel the bolts (Fig. 16/1).
Push the shutter (Fig. 16/2) into the meter-
ing unit up to the stop.
Fig. 82
3. Undo, but do not remove, the two bolts (Fig.
83/1).
Fig. 83