7.5.4
Calibrating the working speed
The on-board computer requires the calibration value "working speed" for the
speed calculation
calculation of the sowing shaft speed
area calculation.
Calibration can be carried out by
travelling a test track
manual calibration.
7.5.4.1
Calibration (working speed) by travelling a test track
1. Measure and mark out a distance of exactly 100 m.
2. Call up the menu and confirm with the
button
3. Confirm the screen display with the
button.
4. Drive exactly the measured distance.
5. Stop after exactly 100 m and press the
button.
Display at the end of calibration
(the display returns to the main menu after a few seconds).