Settings
Centaya Super BAH0092-6 10.20
161
8.11
One-sided switching
Deactivate the one-sided switching at the end of the field pass.
8.11.1 One-sided switching - Installing an insert
DANGER
Dressing dust is toxic and must not be inhaled or come into
contact with the body.
Wear protective clothing, breathing mask, safety glasses
and gloves
when filling the implement
when removing dressing dust
when emptying the hopper and metering unit
when working on the distributor head.
1. Perform work on the distributor head from
the loading board, see section "Safety
when working on the distributor head",
page 193.
2. Open the distributor head cover.
2.1 Loosen the knurled screw (Fig.
207/1) and remove the cover (Fig.
207/2) from the distributor head.
3. Mount the insert (Fig. 207/3) in the
distributor head in such a manner that the
seed supply is interrupted to the coulters
of the necessary implement side.
4. Halve the seed rate, (refer to the operating
manual).
"ISOBUS software"
"AmaDrill 2".
Fig. 207