Maintenance and repairs
Centaya Super BAH0092-6 10.20
199
12.5.3 Shutdown of the implement over a long period of time
Before parking the implement for a longer period of time
Set the placement depth to "0" (only pack top seed drills with TwinTeC double disc coulters,
see section "Adjusting and checking the seed placement depth", page 147
Thoroughly clean and dry the coulters. Then preserve the coulters against rust with
environmentally-friendly corrosion protection
Set the coulter pressure to "0", see section "Coulter pressure, seed rate increase, and coulter
lift", page 151.
Open the drain tap (Fig. 246/1) and drain
the water out of the hand wash tank.
Rinse out the hand wash tank. Do not close
the drain tap (danger of freezing).
Fig. 246