Structure and function
70
Centaya Super BAH0092-6 10.20
5.10
Fan
The fan (Fig. 58/1) generates the air current that
carries the seed to the seeding coulters.
The hydraulic motor (Fig. 58/2) drives the fan.
The control terminal displays the current fan
speed and issues an alarm if there is a deviation
from the nominal speed. The percent deviation at
which the alarm should be triggered can be
adjusted (see "ISOBUS Software" operating
manual).
Fig. 58
The fan hydraulic motor is connected to the
tractor hydraulic system.
Fig. 59
Set the fan speed
at the flow control valve of the tractor
(see section 8.4.1)
at the pressure relief valve of the hydraulic
motor (see section 8.4.2),
if the tractor has no flow control valve.
The suction guard screen prevents the suction of
straw residues into the fan under very dry
conditions.
Fig. 60