background image

 

Characteristics

 

      Basic characteristics 

Module  

Name  

AGT 200 

Technology  

GSM ,GPRS, GNSS, BLUETOOTH 

 

GNSS  

GNSS  

GPS, GLONASS, GALILEO, BEIDOU, QZSS,

 

DGPS 

Receiver  

Tracking: 33/99 acquisition channels 

Tracking sensitivity  

-165 dBM  

Accuracy  

< 3 m  

Hot start  

< 1 s  

Warm start  

< 25 s  

Cold start  

< 35 s  

 

Cellular  

Technology 

GSM/GPRS 

2G bands  

Quad-band 850/900/1800/1900 MHz 

GPRS 

GPRS Mobile Station Class B 

Data transfer  
 

GPRS Multi-Slot Class 12 (up to 240 kbps) 

Data support 

SMS (text/data) 

 

Power  

Input voltage range  

10-30 V DC with overvoltage protection  

Back-up battery  

550 mAh 8,4V Ni-MH battery 

2 W max.

 

Current consumption  

at 12 V 

GPRS: average 69 mA  
Nominal: average 39 mA 
GNSS sleep: average 24 mA 
Deep Sleep: average 7.5 mA 
Online Deep Sleep: average 2.4 mA 

2 W max.

 

Current consumption  

at 24 V 

GPRS: average 35 mA 
Nominal: average 20 mA 
GNSS sleep: average 12,5 mA 
Deep Sleep: average 3,8 mA 
Online Deep Sleep: average 1.3 mA 

Interface  

Digital Inputs  

Digital Outputs 

4  

Analog Inputs 

1-Wire temperature sensors 

1-Wire iButton 

1  

RS232 

RS485 

1  

CAN J1939 

J1708 

K-Line 

LVCAN/ALLCAN 

GNSS antenna 

External High Gain 

GSM antenna 

External High Gain 

USB 

2.0 Mini-USB 

LED indication 

2 status LED lights 

SIM 

2x SIM Card (Dual-SIM) 

Summary of Contents for AGT200

Page 1: ......

Page 2: ...t channel 4 5 DIN2 Digital input channel 2 6 CAN 2L SAE J1939 CAN interface Low channel 2 7 AIN2 Analog input channel 2 Input range 0 30V 0 10V DC 8 DOUT3 Digital output Open collector output 9 DOUT2 Digital output Open collector output 10 AIN3 Analog input channel 3 Input range 0 30V 0 10V DC 11 VCC Power supply 10 30 V DC 12 CAN 1H SAE J1939 CAN interface High channel 1 13 1WIRE DATA Data channe...

Page 3: ...ta transfer Wiring scheme AGT 200 Wiring scheme Set up your device How to insert Micro SIM card and connect the battery 1 Unscrew 4 screws counter clockwise that are located on the bottom of the device 2 Remove the cover 3 Insert SIM card as shown with PIN request disabled or read Security info how to enter it later in Amber Configurator Make sure that SIM card cut off corner is pointing forward t...

Page 4: ...ng wires it should be applied again 4 If the wires are placed in the exterior or in places where they can be damaged or exposed to heat humidity dirt etc additional isolation should be applied 5 Wires cannot be connected to the board computers or control units Connecting power source 1 Be sure that after the car computer falls asleep power is still available on chosen wire Depending on car this ma...

Page 5: ...crub paint from the spot where loop is going to be connected PAY ATTENTION Connecting the power supply must be carried out in a very low impedance point of on board vehicle network Connecting the GND at an arbitrary point to the mass of the car is unacceptable as static and dynamic potentials on the line GND will be unpredictable which can lead to unstable AGT400 M operation and even its failure L...

Page 6: ...h overvoltage protection Back up battery 550 mAh 8 4V Ni MH battery 2 W max Current consumption at 12 V GPRS average 69 mA Nominal average 39 mA GNSS sleep average 24 mA Deep Sleep average 7 5 mA Online Deep Sleep average 2 4 mA 2 W max Current consumption at 24 V GPRS average 35 mA Nominal average 20 mA GNSS sleep average 12 5 mA Deep Sleep average 3 8 mA Online Deep Sleep average 1 3 mA Interfac...

Page 7: ...GPRS commands Configuration DOUT control Time Synchronization GPS NITZ NTP Fuel monitoring LLS Analog LV CAN ALL CAN CAN FMS RS232 RS485 Fuel Sensor Ultrasonic level sensor Ignition detection Digital Input Accelerometer External Power Voltage Physical specification Dimensions 104 1 x 76 8 x 31 5 mm L x W x H Weight 197 g Operating environment Operating temperature without battery 40 C to 85 C Stor...

Page 8: ...essage contains information on how to operate AGT 200 safely By following these requirements and recommendations you will avoid dangerous situations You must read these instructions carefully and follow them strictly before operating the device The device uses SELV limited power source The nominal voltage is 12 V DC The allowed voltage range is 10 30 V DC To avoid mechanical damage it is advised t...

Page 9: ... a PC with autonomic power supply Installation and or handling during a lightning storm is prohibited The device is susceptible to water and humidity Certification and Approvals AGT400 M CE RED AGT400 M CE E Mark AGT400 M CE REACH AGT400 M CE Declaration of IMEI assignment AGT400 M CE Declaration of device operation temperature AGT400 M CE RoHS AGT400 M CE EAC This sign on the package means that i...

Page 10: ...ct should fail within this specific warranty time the product can be Repaired Replaced with a new product Replaced with an equivalent repaired product fulfilling the same functionality Amber can also repair products that are out of warranty at an agreed cost Warranty Disclaimer Amber products are intended to be used by persons with training and experience Any other use renders the limited warranti...

Page 11: ......

Reviews: