Point cloud measurements
User manual
Page 20 of 68
© Amberg Technologies, 2018
Software
Hardware
Re-positioning type
Amberg Navigator
Tablet
Instrument with: Amberg Scanner, ZF Scan-
ner and Faro Scanner
Resection and APM
Amberg Scan Con-
trol
Amberg Scanner, ZF Scanner and Faro
Scanner
APM
Amberg TMS Office
Amberg Scanner, ZF Scanner and Faro
Scanner
APM
Faro Scene
Faro Scan
Checkerboard,
Spheres
Z+F LaserControl
ZF Scan
Checkerboard,
Spheres
Other
E.g PTS, ASCII ...
not available
Open the
Point cloud
editor of the construction stage containing the point clouds that should
be repositioned. Select the measured point cloud that you want to reposition (Multi selection
with same point cloud type is possible). Use the function
Reposition
button from the toolbar
or from the context menu. The
Reposition point cloud data wizard
will guide you through
the process.
The selected point clouds must contain positioning information in order to enable the
Reposition measured point cloud
function. Check the property
Repositioning infor-
mation available
in the property window to see if a profile contains positioning infor-
mation.
To reposition measured point clouds successfully, the control points used during the
point cloud measurement must be available in the
Control points
editors of the project.
3.8.1 Reposition of instrument
The steps of the
Reposition of the instrument for point cloud data wizard
are described
following.
1. Select the state (date and time) at which the control point coordinates should be used.
2. Check the recalculation of the resection.