Point cloud measurements
User manual
Page 22 of 68
© Amberg Technologies, 2018
The repositioning functionality recalculates the point cloud points and replaces the parameters
of the instrument position as displayed in the lower table of the wizard step 2. The measure-
ments to the control points in the instrument positioning information remain unchanged.
3.8.2 APM reposition of point cloud
The steps of the
Reposition point cloud data wizard
are described following. (If measurement
was done with
Amberg Navigator Tablet
the APM point cloud reposition wizard will start direct
after the
Reposition of Instrument
wizard).
1. Select the corresponding file format (GSI, ASCII or DBX) which contains all positioning mea-
surements.
The ASCII file has to contain point id,easting, northing and height information per
row and point. Every column is separated by a space.
Figure 7. APM ASCII file example
2. The program now calculates the position of the rotation center of the first scan file and an
orientation (only based on the two prism measurements on the scanner). The spere will be
detected automatically and the cross should be adjusted to the center. In case the sphere
(Amberg Scan Target) will not be found the sphere center can be selected with a mouse
klick in the picture.
Figure 8. Reposition point cloud data wizard, APM reposition calculation
Point to selected position
Mark the sphere position with manually click to the
sphere.