Analysis and reporting
User manual
Page 34 of 68
© Amberg Technologies, 2018
Figure 20. Settings dialog, Computation - Data filters
Data filter
Amberg Tunnelscan offers different geometrical filters:
■
Trim lines
: If this option is activated, the active trim lines are applied to the
evaluation of this analysis. The values entered correspond to the distance
from the axis point. For example, the left trim line filters out everything left
of the entered value.
■
Trim angle
: If this option is activated, the trim angle is applied to the eval-
uation of this analysis. The trim angle section is defined by the center point
coordinate (relative to the axis) and two angle values (from angle to angle,
relative to zenith).
The geometrical data filters respect the transverse slope definition of the reference
construction stage selected for this analysis.
4.1.3.8 Visualisation - Background
Modify the appearance of the report background.
Figure 21. Settings dialog, Visualisation - Background
Coordinate grid
If this option is activated, the coordinate grid is displayed in the back-
ground. Set the grid width:
■
Automatic
: Let Amberg Tunnelscan choose the appropriate grid
width automatically.