50D0112
RCSTEBA Installation & Operating Manual
Rel 1.0 April 2009
Page 9 of 10
Ambient Technologies
A Division Of
Monessen Hearth Systems
Blower Type Selection:
1.
The remote control can work with different type/size of blowers. The three levels of blower speeds
(High/Medium/Low) can be fine tuned using the blower switches. See figure below for location of the
switches.
2.
In the event that the blower runs too slow or too fast on Low or Medium, change the blower switch setting
to achieve desired speed levels.
3.
Turn on the blower at Low speed with the transmitter and
start from STEP 1
(ON/ON/OFF), then follow
the following steps in the chart below to set up the blower switches. The blower speed will decrease when
going through the steps.
Stop when the desired speed level of Low is achieved.
4.
To asure that the proper Low is selected, run through Low, Medium, High to check all speeds to
achieve the desired best speed levels.
NOTE
It is very important that the Low speed is not too low that to overheat blower motor.
Selection Steps
DIP5
DIP6
DIP7
STEP 1
ON
ON
OFF
STEP 2 (DEFAULT)
ON
ON
ON
STEP 3
OFF
ON ON
STEP 4
OFF OFF
ON
STEP 5
OFF OFF OFF
WAR
N
ING
To avoid overheating the blower when the blower runs too slow, always start from higher
speed (from STEP 1) when adjusting speed levels using the blower switches. And stop trying
the rest of the settings when desired speed level of Low is achieved.
Optional Auto Shutdown:
5.
The receiver comes preset from the factory with a 6 hour shutdown from its last ON operation. This is
done to prevent the appliance from continuing to run if unattended.
6.
You may disable this feature if you wish. To disable, change the receiver privacy (DIP) switch #1 ONLY