background image

 

Version 1.1  

 

©Copyright 2014, Ambient LLC. All Rights Reserved. 

 

 

 

Page 4 

2.4 Display Console Set Up 

 
Move the remote thermometer about 5 to 10’ away from the display console (if the sensor is too close, 
it may not be received by the display console). 
 
Remove the battery door on the back of the display, as shown in Figure 5. Insert two AA (alkaline or 
lithium, avoid rechargeable) batteries in the back of the display console. 
 

 

Figure 5 

 
All of the LCD segments will light up for a few seconds to verify all segments are operating properly. 
 
Replace the battery door, and fold out the desk stand and place the console in the upright position.   
 
The  console  will  instantly  display  indoor  temperature  and  humidity  as  designated  by  the 

  icon.   

The outdoor temperature and humidity will update on the display within a few minutes on Channel 

1

.   

 

While in the search mode, the remote search icon 

  will be constantly displayed. 

 
If  you  have  more  than  once  remote  sensor  (up  to  three  remotes  are  supported),  the  display  will 
automatically toggle between sensors until all sensors have reported in. 
 

Do not touch any buttons until the remote sensor has reported in, or the radio search icon 

  is no 

longer  on,  otherwise  the  remote  sensor  search  mode  will  be  terminated.  When  the  remote  sensor 
temperature  has  been  received,  the  console  will  automatically  switch  to  the  normal  mode,  and  all 
further settings can be performed. 
 
If the remote does not update, please reference the troubleshooting guide in Section 7. 

2.4.1

 

Display Console Layout 

Note: 

The  following  illustration  shows  the  full  segments  of  the  LCD  for  description  purposes 

only and will not appear like this during normal operation. 

Summary of Contents for WS-06

Page 1: ...onsole Layout 4 2 4 2 Sensor Operation Verification 5 3 Remote Sensor Installation 5 4 Console Operation 6 4 1 Set Mode 6 4 2 Min Max Mode 6 4 3 Indoor Outdoor Channel Selection 6 4 4 Sensor Search Mode 6 4 5 Adjustment or Calibration 7 4 5 1 Calibration Discussion 7 4 5 2 Indoor Humidity Calibration 7 5 Glossary of Terms 7 6 Specifications 8 6 1 Wireless Specifications 8 6 2 Measurement Specifica...

Page 2: ...up sequence must be performed in the order shown in this section remote transmitter s first Display Console second The WS 06 weather station consists of a display console receiver and a thermometer remote transmitter 2 1 Parts List QTY Item 1 Display Console Frame Dimensions LxHxW 4 50 x 3 75 x 1 00 in LCD Dimensions LxW 2 75 x 1 75 LCD Segment Height 0 59 inches 1 Thermometer transmitter FT004T D...

Page 3: ...n 4 F and 140 F and fresh lithium batteries for outdoor temperature ranges between 40 F and 140 F Figure 2 3 Close the battery door as shown in Figure 3 Make sure the gasket around the battery compartment is properly seated in its trace prior to closing the door Figure 3 4 After inserting the batteries the remote sensor LED indicator will light for 4 seconds and then flash once per 48 seconds ther...

Page 4: ...outdoor temperature and humidity will update on the display within a few minutes on Channel 1 While in the search mode the remote search icon will be constantly displayed If you have more than once remote sensor up to three remotes are supported the display will automatically toggle between sensors until all sensors have reported in Do not touch any buttons until the remote sensor has reported in ...

Page 5: ...h closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 2 F the accuracy is 1 F Allow about 30 minutes for both sensors to stabilize 3 Remote Sensor Installation It is recommended you mount the remote sensor on a north facing wall in a shaded area Direct sunlight and radiant heat sources will result in inaccurate temperature readings Althou...

Page 6: ...e Set Mode 4 2 Min Max Mode The Min Max mode displays the minimum and maximum indoor and outdoor temperature and indoor humidity since reset of the unit for the indoor remote channel 1 2 and 3 sensors Prior to entering the MIN MAX mode press the CH button to select the temperature values you wish to view 1 Display Maximum Press the MIN MAX button once to display the maximum The MAX icon will be di...

Page 7: ...crease the humidity reading in 1 increments To rapidly increase or decrease the humidity reading press and hold the CH or MIN MAX button To return the indoor humidity to the actual or uncalibrated measurement press the SET button Once the displayed indoor humidity equals the calibrated source wait 15 seconds for timeout and the humidity value will stop flashing Discussion Humidity is a difficult p...

Page 8: ...r use lithium batteries in cold weather climates less than 4 F 7 Troubleshooting Guide If your question is not answered here you can contact us as follows 1 Email Support support ambientweather com 2 Live Chat Support www ambientweather com chat html M F 8am to 4pm Arizona Time 3 Technical Support 480 283 1644 M F 8am to 4pm Arizona Time Problem Solution Wireless remote thermometer not reporting i...

Page 9: ...her station at www AmbientWeather com Accessory Description Energizer AAAS Lithium Battery 2 pack Batteries for Long Life and Cold Climates AAA lithium batteries for cold weather climates Ambient Weather SRS100LX Temperature and Humidity Solar Radiation Shield Solar Radiation Shield improves temperature accuracy for hot weather climates Remove the rain guard and install over thermometer Ambient We...

Page 10: ...nd if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the ...

Page 11: ...er than home use 5 applications and uses that this product was not intended 6 the products inability to receive a signal due to any source of interference or metal obstructions and 7 extreme acts of nature such as lightning strikes or floods This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set...

Reviews: