background image

 

Version 1.0  

 

©Copyright 2013, Ambient LLC. All Rights Reserved. 

 

 

 

Page 12 

 
To calibrate temperature, we recommend a mercury or red spirit (fluid) thermometer. Bi-metal (dial) 
and other digital thermometers are not a good source and have their own margin of error. Using a local 
weather station in your area is also a poor source due to changes in location, timing (airport weather 
stations are only updated once per hour) and possible calibration errors (many official weather stations 
are not properly installed and calibrated). 
 
Place  the  sensor  in  a  controlled  environment  next  to  the  fluid  thermometer,  and  allow  the  sensor  to 
stabilize  for  48  hours.  Compare  this  temperature  to  the  fluid  thermometer  and  adjust  the  console  to 
match the fluid thermometer. 

5

 

Glossary of Terms 

 

Term 

Definition 

Accuracy 

Accuracy is defined as the ability of a measurement to match the actual 
value of the quantity being measured. 

Range 

Range is defined as the amount or extent a value can be measured. 

6

 

Specifications 

6.1 Wireless Specifications 

 

Line of sight wireless transmission (in open air): 300 feet, 100 feet under most conditions. 

 

Frequency: 433 MHz 

 

Update Rate: 60 seconds 

6.2 Measurement Specifications 

The following table provides specifications for the measured parameters.   
 

Measurement 

Range 

Accuracy 

Resolution 

Indoor Temperature 

32 to 140 °F 

± 1 °F 

0.1 °F 

Channel 1-8 
Temperature 

-40 to 140 °F 

± 1 °F 

0.1 °F 

6.3 Power Consumption 

 

Base station (display console) : 4 x AAA 1.5V Alkaline or Lithium batteries (not included) 

 

Remote sensor : 2 x AAA 1.5V Alkaline or Lithium batteries (not included) 

 

Battery life:    Minimum 12 months for base station with one sensor and excellent reception. 
Intermittent reception and multiple sensors may reduce the battery life.   
Minimum  12  months  for  thermometer  probe  sensor  (use  lithium  batteries  for  temperatures 
less than -4 °F) 

7

 

Troubleshooting Guide 

If your question is not answered here, you can contact us as follows: 
 

1.

 

Email Support: 

support@ambientweather.com

 

2.

 

Live Chat Support: 

www.ambientweather.com/chat.html

 (M-F 8am to 4pm Arizona Time) 

3.

 

Technical Support: 480-283-1644 (M-F 8am to 4pm Arizona Time) 
 

Summary of Contents for WS-09

Page 1: ...ounting 8 4 Console Operation 9 4 1 Channel Selection 9 4 2 Min and Max Alarm 9 4 2 1 Turning On and Off the Alarm 9 4 2 2 Alarm Defaults 10 4 2 3 Setting the Min and Max Alarm 10 4 2 4 Viewing the Min and Max Alarms 10 4 3 Reset Max Min 10 4 4 Temperature Units of Measure 10 4 5 Sensor Search Mode 10 4 6 Best Practices for Wireless Communication 11 4 7 Adjustment or Calibration 11 5 Glossary of T...

Page 2: ...reezer In addition to the refrigerator freezer application the probe thermometer can be placed in any medium where temperature is required including ground temperature air temperature and water temperature 2 Getting Started Note The power up sequence must be performed in the order shown in this section insert batteries in the remote transmitter s first Display Console second The WS 09 weather stat...

Page 3: ...the first transmitter to Channel 1 refrigerator and the second transmitter to Channel 2 freezer Figure 2 displays all four switches in the OFF position factory default setting Figure 2 3 Channel Number The WS 09 supports up to eight transmitters To set each channel number the default is Channel 1 change Dip Switches 1 2 and 3 as referenced in Table 1 4 Temperature Units of Measure To change the tr...

Page 4: ...sor is transmitting data 7 Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 3 Figure 3 1 temperature 2 temperature units F vs C 3 channel number 8 Close the battery door Make sure the gasket around the battery compartment is properly seated in its trace prior to closing the door Tighten the set screw 2 2 Display Console Set Up 1 Mov...

Page 5: ...be constantly displayed for each sensor If you have more than two remote sensors additional channels 3 8 are supported the display will automatically toggle between sensors until all sensors have reported in Do not touch any buttons until all of the remote sensors has reported in or the radio search icon is no longer visible otherwise the remote sensor search mode will be terminated When the remot...

Page 6: ...r Temperature Indicator 17 Temperature Channels 3 4 5 6 7 8 18 Scroll mode indicator 19 Channel indicator 20 Low battery indicator 21 Channel 2 Temperature 22 Channel 2 Indicator 23 Low battery indicator 2 2 2 Sensor Operation Verification Verify the temperature sensors match closely with the console and sensor array in the same location about 5 to 10 apart The sensors should be within 2 F the acc...

Page 7: ...talling the sensor to the outside of the refrigerator freezer If the refrigerator freezer is a metal box the wireless signal cannot escape and the sensors must be placed on the outside Figure 6 To attach the suction cup to the remote sensor reference Figure 7 1 Locate the mounting hole on the back of the unit 2 Press the suction cup into the mounting hole 3 While applying pressure with your thumb ...

Page 8: ...rface is smooth and clean so that suction cups will not fall off It is recommended to wet the surface of the suction cup first to improve the seal 3 2 Wall Mounting The remote sensor can be mounted to a wall or horizontal surface to measure any temperature medium including air water and soil Use a screw or nail not included to affix the remote sensor to the wall as shown in Figure 8 Note If measur...

Page 9: ...n and max temperature alarm on the Channel 1 and Channel 2 thermometers If the alarm is exceeded for more than 10 minutes as audible alert will occur and the alarm value will flash To silence the alarm press any button To set the alarm or adjust the min and max alarm settings press the CHANNEL button until the channel indication arrow points at the selected channel 4 2 1 Turning On and Off the Ala...

Page 10: ...ointing at the appropriate channel press and hold the CLEAR button for 3 seconds to restore the MAX and MIN values to the current value 4 4Temperature Units of Measure With the indicator arrow pointing at the indoor temperature channel press and hold the ALARM button for 3 seconds to change between degrees Celsius and degrees Fahrenheit units of measure 4 5 Sensor Search Mode If any of the sensor ...

Page 11: ...ent can be adjusted from the console to calibrate to a known source Calibration is only useful if you have a known calibrated source you can compare it against and is optional This section discusses practices procedures and sources for sensor calibration to reduce manufacturing and degradation errors Do not compare your readings obtained from sources such as the internet radio television or newspa...

Page 12: ... value can be measured 6 Specifications 6 1 Wireless Specifications Line of sight wireless transmission in open air 300 feet 100 feet under most conditions Frequency 433 MHz Update Rate 60 seconds 6 2 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 32 to 140 F 1 F 0 1 F Channel 1 8 Temperatu...

Page 13: ... batteries in the remote probe thermometer For cold weather environments install lithium batteries Make sure the remote sensors are not transmitting through solid metal acts as an RF shield or earth barrier down a hill Move the display console around electrical noise generating devices such as computers TVs and other wireless transmitters or receivers Move the remote sensor to a higher location Mo...

Page 14: ...al of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Reading the User manual is highly recommended The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of weather conditions Thi...

Page 15: ...ear limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact Ambient LLC for problem determination and service procedures Warranty service can only be performed ...

Reviews: