6.
Specifications
6.1
Measurement Specifications
The following table provides specifications for the measured parameters.
Measurement
Range
Accuracy
Resolution
Temperature
-22 to 199 °F
(-30 to 100 °C)
± 0.9 °F
(± 0.5 °C) at 25°C
± 1.5 °F
(± 0.8 °C) otherwise
0.01 °F / °C
Humidity
0 to 100%
± 2% from 20 to 80%
at 25°C
± 2.5% otherwise
0.01%
6.2
Other Specifications and Features
Display:
Large 4-1/2 dual digital LCD display with backlight
Display Dimensions:
1.5” x 1.5” (38.1 mm x 38.1 mm)
Sensor Type:
Relative humidity and temperature multi sensor module located at the probe
tip with calibrated digital output
Response Time:
%RH: 10 seconds for stabilization in still air, temperature < 0.4 seconds
Sampling Rate:
0.4 seconds
Out of range:
“OL” indication on the display
Low battery indication:
The icon is displayed when the battery voltage drops below
the operating level.
Operating Conditions:
32
o
F to 104
o
F (0
o
C to 40
o
C); < 80% RH non-condensing
Storage Conditions
: 14
o
F to 140
o
F (-10
o
C to 60
o
C); <80% RH non-condensing
Auto Power Off:
Meter automatically shuts down after.15 minutes of inactivity (Sleep
Mode)
To override Auto Power Off function (Non-Sleep Mode), press and hold the
Hold/Backlight
button , then press power button, after the full display appears, and then release both buttons.
The non-sleep mode Icon
will not be displayed on the LCD.
Power:
One standard 9V, NEDA1604 or 6F22 battery.
Dimensions:
8.8 (H) x 1.8 (W) x 1.3 (D) or 225 (H) x 45 (W) x 34 (D) mm
Weight:
0.45 lbs (200g)
7.
Troubleshooting Guide
If your question is not answered here, you can contact us as follows:
1.
Email Support:
support@ambientweather.com
2.
Live Chat Support:
www.ambientweather.com/chat.html
(M-F 8am to 4pm Arizona Time)
3.
Technical Support: 480-283-1644 (M-F 8am to 4pm Arizona Time)
Problem
Solution
Display console contrast is weak
Replace console batteries with a fresh set of batteries.
8.
Liability Disclaimer
Please help in the preservation of the environment and return used batteries to an authorized depot.