Lenses provided

The lenses mounted on the sensor are: volumetric for PIR 1 (upper), horizontal curtain for PIR 2 with rather thick 

beams.  This solution is designed for almost all applications that require a standard installation at about 1.8/2 meters 

high, with the possibility of managing the presence of animals. (fig. above)

Besides the standard configuration, you can use the optional lenses included in the package.

Using the sensor with 2 horizontal curtain lenses: 

you can position the sensor at a height between 80 cm and 1.2 

m based on need. Then adjust the board position based on the beam range.

This way you have a variable height protection from 35/40 cm from the ground and up to 1.6 cm high with a horizontal 

coverage of about 80/100 degrees. With this configuration you can achieve immunity to medium to large animals even 

at considerable distances (15 m).

Using the sensor with 2 vertical curtain lenses: 

the use of vertical curtain lenses is based on the need to protect 

doors and windows with a vertical curtain that is no wider than 50 cm. In this way the protection is only near the doors 

and/or windows without extending into other areas. You can position the sensor at a height of between 1 m and 2 m 

based on need. The beam is about 50 cm wide for an aperture of about 90/100 vertical degrees (fig. below) 

1 2 3 4 5 6

FUNCTIONS

The lenses are attached to the sensor with funnels that are snapped into the housings on the front cover (fig.)

Replacing the lenses

Summary of Contents for soutdoor L

Page 1: ...centage of false alarms With hight thermal variations the totally digital temperature compensation system guarantees a great performance Has 15mt coverage with angle of 90 With usable different type o...

Page 2: ...ed Dip switches EOL resistor jumpers Walk test LED anti opening height adjustment board Installation Place the sensor at a height of between 1 m and 2m Important placement should be chosen depending o...

Page 3: ...ing the direction of the beams As you can see in the picture below you can slide the board inside the cover FUNCTIONS Sliding system detail board The sliding is opposite to the beam so when the board...

Page 4: ...UNCTIONS 1 2 3 4 5 6 FUNCTIONS 1 2 3 4 5 6 FUNCTIONS Coverage diagrams based on board position Note the figures show the effect of the beams based on the position of the board Since they are purely in...

Page 5: ...ackage there are 3 types of lenses Horizontal curtain lens Fig 1 Vertical curtain lens fig 2 Volumetric curtain lens fig 3 On the sensors are mounted by default on the PIR1 top the volumet ric lens an...

Page 6: ...the beam range This way you have a variable height protection from 35 40 cm from the ground and up to 1 6 cm high with a horizontal coverage of about 80 100 degrees With this configuration you can ac...

Page 7: ...be positioned towards the outside Important the volumetric lens has one direction therefore pay close attention to how it is positioned When put up against the light you can see how the FRESNEL lenses...

Page 8: ...nt the positioning mentioned previously Note remember that the distance between the board and the base is 13 5 mm Space reserved for the proper positioning of the cable feeder or any piping to be inse...

Page 9: ...he manufacturer shall not be responsible if the product is tampered with by unauthorised persons We recommend that you check the correct operation of the alarm system at least once per month A reliabl...

Reviews: