20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
NXEE2 User Manual
I
NSTALLING
THE
NXEE2
29
1.6 SSI Transducer Wiring (continued)
1.6.1 AMCI DC25 SSI DuraCoder Wiring
Table T1.1 below lists wire colors of the CSL-(x) cable for the AMCI DC25 SSI DuraCoder along with con-
nections to the NXEE2.
Table T1.1 DC25 SSI DuraCoder Wiring
1.6.2 Extending the Sensor Cable
Your sensor manufacturer should have a suggested cable if you need to extend the sensor cable. If you cannot
find a suggested cable, the following Belden cables can be used. Three is the minimum number of pairs
needed for an SSI sensor. If your sensor has additional signals, then choose a cable with additional pairs.
AMCI uses Belden 1423A or equivelent for our CSL-(x) cable.
Table T1.2 Suggested Extension Cables
Signal
CSL-(x)
Wire COlor
Pin #
J1 for CH1
J2 for CH2
Notes
GNDsensor
BLU/RED
6
See
on page 30 for addi-
tional information on powering the sensor.
+Vsensor
RED/BLU
5
–Data
WHT/BLU
4
+Data
BLU/WHT
3
–CLK
WHT/ORN
2
+CLK
ORN/WHT
1
SHIELD
Bare Wire
10 or DIN rail
Shield must be connected to chassis ground. If wire
will not fit in pin 10, attach to grounded DIN rail.
Reset
GRY/WHT
No Conn.
100mS positive pulse resets position to zero.
Count Dir.
WHT/GRY
See Note
Float, or connect to GNDsensor for CW increasing.
Connect to +Vsensor for CCW increasing
–RS485 Tx
WHT/GRN
No Conn.
Serial interface used during DC25 configuration.
+RS485 Tx
GRN/WHT
No Conn.
Serial interface used during DC25 configuration.
–RS485 Rx
WHT/BRN
No Conn.
Serial interface used during DC25 configuration.
+RS485 Rx
BRN/WHT
No Conn.
Serial interface used during DC25 configuration.
Belden #
# of Pairs
1420A
3
1421A
4
1422A
5
1423A
6
Summary of Contents for NXEE2
Page 22: ...DATA FORMATS NXEE2 User Manual ADVANCED MICRO CONTROLS INC 22 Notes ...
Page 32: ...INSTALLING THE NXEE2 NXEE2 User Manual ADVANCED MICRO CONTROLS INC 32 Notes ...
Page 40: ...SET THE IP ADDRESS AND PROTOCOL NXEE2 User Manual ADVANCED MICRO CONTROLS INC 40 Notes ...
Page 42: ...PROTOCOL SPECIFIC INFORMATION NXEE2 User Manual ADVANCED MICRO CONTROLS INC 42 Notes ...
Page 54: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 54 Notes ...
Page 60: ...ETHERNET IP EXPLICIT MESSAGING EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 60 Notes ...