Specifications

Model Number

ALD-12,000E

ALD-12,000EH

Cooling Capacity

12,000 BTU/hr

12,000 BTU/hr

Heating Capacity

N/A

12,000 BTU/hr

Power Consumption

950W / 8.4A

950W / 8.4A

Humidity Removal Capacity

65 Pts. / Day

65 Pts. / Day

Recommended room size*

Up to 400 sq. ft.

Up to 400 sq. ft.

Power Supply

115V / 60Hz / 1 Phase

115V / 60Hz / 1 Phase

Compressor

Rotary

Rotary

Refrigerant

R-22

R-22

Fan Speed

2

2

Timer

1-12 hours

1-12 hours

Temperature Set Range

62

°

F - 90

°

F

62

°

F - 90

°

F

Unit Weight

65 lbs.

68 lbs.

Dimensions

16"W x 17"D x 30"H

16"W x 17"D x 30"H

Working Temperature

Cooling: 62

°

F to 110

°

F

Cooling: 62

°

F to 110

°

F

Heating: 41

°

F to 81

°

F

REMARKS:

The cooling capacity of the unit may be affected  by the height of the ceiling,
quality of insulation, number of windows, etc.

Drainage

During the process of cooling, some water will be extracted from the air into the unit.  Most of this water
is used to cool the unit and make it run more efficiently.  This is a feature not found in most Portable Air
Conditioners.  If the unit is operated in VERY HUMID air, water will collect in the container inside the unit.
If the Internal Water Container is full, the backlight on the LCD display will flash, the unit will shut off, and
it must be drained before it will re-start.

How to Drain the Unit

Use a Shallow Container or Dish

1. Turn off the unit.

2. Position a flat container or dish under the drain hole.

Do not allow the water to drip continuously into
the container, as it might easily overflow.

3. Remove the drain knob & rubber plug from

the drain hole.
The condensed water will drain out automatically.

4. When the container is almost full, replace the

rubber plug into the drain hole to stop the water.
Empty the container.

5.  Repeat steps 2, 3 & 4 until all the condensed water

is emptied.

6.  Once all the condensed water has been removed,

replace the rubber plug into the drain hole firmly.
The Full Water indicator should be off now.

7.  Replace the drain knob.

8. Turn unit on, the unit will resume working.

Summary of Contents for 000E

Page 1: ... for which it was not designed or 4 repaired or altered in any way that adversely affected its performance or reliability To obtain warranty service the defective product or part must be shipped or delivered to Amcor s authorized service center All postage insurance and shipping charges are the responsibility of the Purchaser and are not included in this warranty AMCOR NEITHER ASSUMES NOR AUTHORIZ...

Page 2: ... and windows are open The filter is dirty Clean or replace filter Air inlet or air Remove blockage outlet is blocked Room temperature lower Lower temperature selected than the selected value The overheat protection Wait 3 minutes until temperature is activated has decreased then turn on again No power supply Make sure outlet works Be sure Green Light is on L C D I Plug Press Re start button Water ...

Page 3: ... cool the unit and make it run more efficiently This is a feature not found in most Portable Air Conditioners If the unit is operated inVERY HUMID air water will collect in the container inside the unit If the Internal Water Container is full the backlight on the LCD display will flash the unit will shut off and it must be drained before it will re start How to Drain the Unit Use a Shallow Contain...

Page 4: ...econd Note When unit is in the following modes Auto Cool or Heat the compressor will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve energy the compressor will not start immediately after a couple degrees increase or decrease but will wait for a 5ºF allowance For example ...

Page 5: ... 2 Attach Slide Bar Connector Round Connector to the other end of the Hose by extending hose at least 6 Then tighten Hose by turning the Round Connector clockwise 3 Place Adjustable Slide Bar in the window and expand so it fits tightly 4 Lower the window 5 Make sure the Hose has no kinks Slide Bar has 3 sections which allows installation in windows up to 48 in width Wall Connection 1 Make a hole 5...

Page 6: ...e is HIGHER than the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heating will resume This machine is equipped with an ANTI FROST function Sometimes while using the heating function during low temperatures the heating will stop for a while to melt the internal frost When this occurs wait for heating to resume As you switch on the h...

Page 7: ...wer Cord When the unit is not in use please store the power cord away as shown in Figure 3 Thank You Thank you for choosing the portable air conditioner from AMCOR a leading brand in indoor air treatment We would like you to enjoy the many benefits this unit offers so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Air Conditioner offers you ...

Reviews: