TABLE. ELECTRICAL SYSTEM TROUBLESHOOTING (cont'd)
Trouble
Cause
Remedy
STARTER
Motor fails to operate.
Low battery charge.
Defective or improper wiring or
loose connections.
Defective starter solenoid or
control switch.
Check and recharge if necessary.
Refer to electrical wiring
diagram and check all wiring.
Replace faulty unit.
Low motor and cranking speed.
Worn, rough, or improperly
lubricated motor or starter
gearing.
Same electrical causes as listed
under "Motor fails to operate".
Disassemble, clean, inspect, and
relubricate, replacing ball
bearings if worn.
Same remedies listed for these
troubles.
ELECTRICAL LOADS (AMPS)
Equipment
Continuous
Intermittent
Battery solenoid
Voltage Regulator
Clock
Hour meter
Fuel Gauge
Fuel Pressure
Oil Temperature
Voltmeter
Ammeter
Aux. fuel pump
Flap Actuator
Trim Actuator (if applicable)
Nav. Light
Landing Light
Strobe
Starter
Pitot Heat
Flaps
Trim
Field
XPND
COM
GPS
.65
3.0
.1
.1
.1 (ea)
.1
.1
.1
.1
10
10
10
2
3
1
2
5.0
2.0
2.0
10
10
2
4
10.4