Congratulations on your purchase of the Tech-Scan 32™ Plus Scanning with Environmental Controls Communicator. T

HE 

T

ECH

-S

CAN 

32

 

P

LUS 

ECU

 IS A MULTI

-

LEVEL

,

 

3

 

M

ODE SCANNING 

A

UGMENTATIVE COMMUNICATOR THAT OFFERS HIGH QUALITY

,

 RELIABLE PERFORMANCE

,

 AS WELL AS MANY OTHER IMPORTANT FEATURES FOR A 

VERY AFFORDABLE PRICE

.

  

T

ECH

-S

CAN

32

 

P

LUS 

ECU

 IS MANUFACTURED TO THE HIGHEST COMMERCIAL STANDARDS TO PROVIDE MANY YEARS OF RELIABLE OPERATION

.

 

W

E FULLY GUARANTEE THE 

T

ECH

-S

CAN

32

 

P

LUS 

ECU’

S OPERATION FOR A FULL YEAR

,

 INCLUDING PARTS AND LABOR

.* 

 

D

ISTINCTIVE 

F

EATURES OF THE 

T

ECH

-S

CAN 

32

 

P

LUS 

ECU

 

 

 

S

CANNING 

Q

UES 

(LED

S

)

 ARE  IN THE GRID

,

 ABOVE THE OVERLAY

,

 MAKING OVERLAYS SIMPLE TO PRODUCE

.

 

N

O NEED TO PUNCH 

HOLES

.

 

 

V

ERY 

S

IMPLE TO OPERATE

,

 

5

 SWITCHES ON THE BACK CONTROL ALL FUNCTIONS  

 

 

S

TANDARD 

R

ECHARGEABLE 

B

ATTERY 

P

ACK

 

PROVIDES YOU WITH UP TO EIGHT HOURS OF USE WITH A RECHARGING TIME OF ONLY FOUR 

HOURS

.

 

 

S

INGLE OR DOUBLE SWITCH OPERATION FROM AN EXTERNAL SWITCH

 

 

A

UTO 

S

LEEP WHEN 

T

ECH

-S

CAN 

32

 

P

LUS 

ECU

 IS INACTIVE FOR 

5

 SWEEPS AND 

W

AKENS WITH A TOUCH OF THE USER SWITCH

 

P

ROGRAM UP TO 

32

 

AC

 REMOTE OUTLET RECEIVERS OR LIGHT BULBS

 

P

ROGRAM UP TO 

8

 DIFFERENT 

I

NFRARED CONTROLS

.

 

S

UCH AS  

P

OWER

,

 

C

HANNELS OR 

V

OLUME

 

D

ROP RESISTANT

,

 ABLE TO WITHSTAND ROUGH HANDLING

 

W

ATER RESISTANT FOR EASY CLEANING

.

 

 

 

A

UDITORY PROMPTS FOR EACH MESSAGE

 

 

L

IGHT WEIGHT AND PORTABLE 

(

UNDER 

2

 LBS

.)

 WITH A 

S

HOULDER 

S

TRAP INCLUDED

 

 

“R

EAL

-V

OICE

 

HIGH QUALITY AUDIO REPRODUCTION

 

A

LLOWS YOU TO PROGRAM

,

 RECORD AND PLAYBACK 

192

 INDEPENDENT MESSAGES ON 

6

 LEVELS

,

 

32

 MESSAGES PER LEVEL

 

 

 

C

AN BE USED AS EITHER A SCAN OR AS A STANDARD COMMUNICATOR

,

 LIKE HAVING 

2

 COMMUNICATORS IN ONE

 

I

NTERCHANGEABLE 

O

VERLAYS WHICH ARE COMPATABLE WITH 

M

AYER 

J

OHNSON 

BOARDMAKER™

 

S

OFTWARE WHICH EXTENDS 

USABLITY

                                                    

*

 

S

EE 

W

ARRANTY 

A

GREEMENT FOR DETAILS

 
GENERAL OPERATION: 
 

 

All controls are located on the back of the Tech-Scan32 Plus ECU (see diagram – BACK VIEW)

The Tech-Scan32 Plus ECU scanning augmentative communicator is a self-contained 6 level communication device, which permits the user to 
record  and  playback  192  distinct  messages, each  of  3.0  seconds in  length  (or  7.5  seconds  for  extended time).    The  Tech/Scan 32  Plus  ECU 
allows you to control 32 independent AC remote outlets as well as 8 different Infrared control signals. The Tech-Scan32 Plus ECU is simple to 
operate. By turning the unit on, adjusting the volume, selecting the desired level and scan mode and pushing the message square or external 
switch, the communicator is activated. 

NOTE: The top 8 cell locations from left to right on LEVEL 1 are used for the 32 remote AC outlets. In 1 cell location 8 different AC 
remotes can be programmed to that location to turn ON only. There are 4 pairs to be programmed, that equals 32 AC remotes. Level 2 
is for the Infrared controls. Each cell can control a different Infrared command. Levels 3 to 6 are all for communication. 
 

 

                               

 

Summary of Contents for TECH-SCAN32 PLUS

Page 1: ...UDITORY PROMPTS FOR EACH MESSAGE LIGHT WEIGHT AND PORTABLE UNDER 2 LBS WITH A SHOULDER STRAP INCLUDED REAL VOICE HIGH QUALITY AUDIO REPRODUCTION ALLOWS YOU TO PROGRAM RECORD AND PLAYBACK 192 INDEPENDENT MESSAGES ON 6 LEVELS 32 MESSAGES PER LEVEL CAN BE USED AS EITHER A SCAN OR AS A STANDARD COMMUNICATOR LIKE HAVING 2 COMMUNICATORS IN ONE INTERCHANGEABLE OVERLAYS WHICH ARE COMPATABLE WITH MAYER JOH...

Page 2: ...the level selector switch to one of the six levels 3 Set the PROGRAM switch to the type of message that you wish to record on AUDITORY NORMAL or ROW prompt see diagram BACK VIEW Programming the Auditory Prompts 1 Set the Program Mode select switch to the left position labeled AUDI you will be recording the auditory prompts These prompts have a maximum message length of 1 5 seconds 2 Press and hold...

Page 3: ... jack labeled Switch Input 1 is activated it will advance to the next ROW from ROW 1 to ROW 4 and then back to ROW 1 When the desired ROW is lit press the external switch plugged into the jack labeled Switch Input 2 then the LED in Column 1 of that ROW will light To advance the LED to light in the next Column activate the external User switch plugged into Switch Input 1 Each time the external User...

Page 4: ...ng unit 1 Plug in the external switch into the jack labeled Switch Input 1 for SINGLE SWITCH scanning and Switch Inputs 1 2 for DOUBLE SWITCH scanning on the back 2 Select the LEVEL select switch to the LEVEL you wish to playback by turning the level selector switch to one of the six levels 3 Select the Scan MODE Linear Row Column or Step see Selecting Scan Mode 4 Select the Scan SPEED Slow Medium...

Page 5: ...let will turn on The Remote Light Bulb will turn OFF 11 Select the position you want to store the Programming ID code into A B C or D on the left side of the keypad in the ON column A is for the first position J1 on the diagram GRID VIEW top left position on the front of the device B is for the next position to the right J2 C is for J3 D is for J4 All the top membrane positions J1 to J4 are used t...

Page 6: ...ONTROL LOCATIONS 1 Place the unit on a flat stable surface 2 Set the level Select switch to Level 2 3 Turn the power On by turning the Volume control clockwise 4 Set Programming Switch IR1 SW2 on the Programming Keypad to the ON position see diagram below 5 Point the transmitting LED of your remote that you what to copy directly at the infrared receiver on the Programming Keypad see diagram below ...

Page 7: ...t sponge with cold water to wipe the soapy areas CARE AND MAINENANCE The Tech Scan32 Plus ECU is designed to automatically enter a sleep mode after a message is played The sleep mode is still an active mode and will affect battery life If the Tech Scan32 Plus ECU is not going to be used for a long period of time 2 to 3 hours it is recommended that the unit be turned off If the Tech Scan32 Plus ECU...

Reviews: