background image

RECHARGABLE BATTERY PACK:

 

THE  RECHARGEABLE  BATTERY  PACK  IS  A  STANDARD  FEATURE  ON  THE  TECH-SCAN  32  PLUS  ECU  AND 
PROVIDES  YOU  WITH  UP  TO  EIGHT  HOURS  OF  USE  WITH  A  RECHARGING  TIME  OF  APPROXIMATELY  FOUR 
HOURS. IT IS RECOMMENDED THAT THE UNIT BE FULLY CHARGED BEFORE USING FOR THE FIRST TIME. 

1.

 

To charge the battery pack, plug the charging unit into an AC outlet. 

2.

 

Plug the other end of the charger into the front of the Tech-Scan 32 Plus ECU. The charging LED will light, (RED for 
charging). 

3.

 

When the charging LED changes to GREEN, the battery pack is fully charged. 

4.

 

It is recommended that the unit be recharged nightly. 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
RECORD OPERATION: 
 
Note: It is important during any recording operation that the  built in microphone, located  on the front right  hand corner of 
the  Tech-Scan  32  Plus  ECU  (see  diagram  –  FRONT  VIEW),  is  clear  and  open.  For  best  results,  place  unit  on  a  flat  surface 
with the microphone facing you and record all messages in a quiet room.  Be sure that the External User switch is not plugged 
into the  unit while  you are recording. It is recommended that  you record all the Auditory Prompts at  one time, then all the 
Normal Messages at one time to prevent having to switch back and forth between the 2 modes. 
 

1.

 

Turn the Tech-Scan 32 Plus ECU ON by turning the 

VOLUME

 control switch clockwise, until it clicks ON. 

2.

 

Select the 

LEVEL

 you wish to record on by turning the level selector switch to one of the six levels. 

3.

 

Set  the 

PROGRAM

  switch  to  the  type  of  message  that  you  wish  to  record  on  AUDITORY,  NORMAL,  or  ROW  prompt               

(see diagram – BACK VIEW). 

 

Programming the Auditory Prompts

 
1.

 

Set the 

Program

 Mode select switch to the left position labeled 

AUDI

, you will be recording the auditory prompts.  These 

prompts have a maximum message length of 1.5 seconds. 

2.

 

Press and hold in the built-in record switch.  

The record switch must be engaged for the entire recording process. 

3.

 

Select one of the 32 message squares on the face of the Tech-Scan 32 Plus ECU, press and hold down that message square. 
Then begin to say your message into the built in microphone located at the front right hand corner of the Tech-Scan 32 Plus 
ECU. 

4.

 

Release the message square when you are finished recording that message. 

5.

 

Repeat steps 2 through 4 for the remaining message squares. 

 

Programming the Normal Messages: 

   
1.

 

Set the 

Program

 Mode  select switch  into  the  middle position,  marked 

NORMAL

,  you  will  be  recording  the  full  message 

itself;  follow  steps  above    (Programming  the  Auditory  Prompts)  2  to  4  to  program  each  message.   These  messages  have  a 
maximum message length of 3.0 seconds for standard units and 7.5 seconds for extended time units. 

 

Programming the Row Prompts: 

 
1.

 

Set the 

Program

 Mode select switch to the right position marked 

ROW

, you will be recording the row titles.  Follow steps 

above  (Programming  the  Auditory  Prompts)  2  to  4  to  program  each  row  title,  use  the  first  message  square  in  each  row. 
Maximum message length for each ROW prompt is 1.5 seconds. 

 

 

 

Summary of Contents for TECH-SCAN32 PLUS

Page 1: ...UDITORY PROMPTS FOR EACH MESSAGE LIGHT WEIGHT AND PORTABLE UNDER 2 LBS WITH A SHOULDER STRAP INCLUDED REAL VOICE HIGH QUALITY AUDIO REPRODUCTION ALLOWS YOU TO PROGRAM RECORD AND PLAYBACK 192 INDEPENDENT MESSAGES ON 6 LEVELS 32 MESSAGES PER LEVEL CAN BE USED AS EITHER A SCAN OR AS A STANDARD COMMUNICATOR LIKE HAVING 2 COMMUNICATORS IN ONE INTERCHANGEABLE OVERLAYS WHICH ARE COMPATABLE WITH MAYER JOH...

Page 2: ...the level selector switch to one of the six levels 3 Set the PROGRAM switch to the type of message that you wish to record on AUDITORY NORMAL or ROW prompt see diagram BACK VIEW Programming the Auditory Prompts 1 Set the Program Mode select switch to the left position labeled AUDI you will be recording the auditory prompts These prompts have a maximum message length of 1 5 seconds 2 Press and hold...

Page 3: ... jack labeled Switch Input 1 is activated it will advance to the next ROW from ROW 1 to ROW 4 and then back to ROW 1 When the desired ROW is lit press the external switch plugged into the jack labeled Switch Input 2 then the LED in Column 1 of that ROW will light To advance the LED to light in the next Column activate the external User switch plugged into Switch Input 1 Each time the external User...

Page 4: ...ng unit 1 Plug in the external switch into the jack labeled Switch Input 1 for SINGLE SWITCH scanning and Switch Inputs 1 2 for DOUBLE SWITCH scanning on the back 2 Select the LEVEL select switch to the LEVEL you wish to playback by turning the level selector switch to one of the six levels 3 Select the Scan MODE Linear Row Column or Step see Selecting Scan Mode 4 Select the Scan SPEED Slow Medium...

Page 5: ...let will turn on The Remote Light Bulb will turn OFF 11 Select the position you want to store the Programming ID code into A B C or D on the left side of the keypad in the ON column A is for the first position J1 on the diagram GRID VIEW top left position on the front of the device B is for the next position to the right J2 C is for J3 D is for J4 All the top membrane positions J1 to J4 are used t...

Page 6: ...ONTROL LOCATIONS 1 Place the unit on a flat stable surface 2 Set the level Select switch to Level 2 3 Turn the power On by turning the Volume control clockwise 4 Set Programming Switch IR1 SW2 on the Programming Keypad to the ON position see diagram below 5 Point the transmitting LED of your remote that you what to copy directly at the infrared receiver on the Programming Keypad see diagram below ...

Page 7: ...t sponge with cold water to wipe the soapy areas CARE AND MAINENANCE The Tech Scan32 Plus ECU is designed to automatically enter a sleep mode after a message is played The sleep mode is still an active mode and will affect battery life If the Tech Scan32 Plus ECU is not going to be used for a long period of time 2 to 3 hours it is recommended that the unit be turned off If the Tech Scan32 Plus ECU...