4
2.3 Installation Procedures
2.3.1 Step by Step Installation Instructions
Please follow the steps below to install PASO-350.
1.
Ensure the standard 19-inch rack is firmly fixed.
2.
Position PASO-350 on the rack and aligning the holes on the brackets with the holes on the rack, and
then use the screws to mount PASO-350.
3.
Connect 100 ~ 240V AC or +24V DC cable from battery bank to PASO-350
’s power terminals.
4.
Ensure the power terminals for 100 ~ 240V AC and/or +24V DC are proper fixed.
5.
Connect LCT cable (from PASO-350 front panel) to laptop or PC to configure PASO-350.
2.3.2 Connector Pin Definition and Wiring
The wiring details of the LCT/ NMEA 0183/ ALARM connectors are listed below.
2.3.2.1 LCT (local Craft Terminal) Connector
Pin
Name
Function
2
Rx
LCT data receiver
3
Tx
LCT data transmitter
5
GND
Ground
2.3.2.2 NMEA 0183 Connector
Pin
Name
Function
1
RXP
Positive(
+
); NMEA0183 Data input
2
RXN
Negative (
-
); NMEA0183 Data input
3
TXP
Positive(
+
); NMEA0183 Data output
4
TXN
Negative (
-
); NMEA0183 Data output
2.3.2.3 ALARM Connector
Pin
Name
Function
1
ALM A
Alarm contact A
2
ALM B
Alarm contact B