background image

PN 05615

 

 

 

 

 

 

 

04/2020

 

#

 

NOTES

 

1

 

THIS COVERSHEET FOR INFORMATIONAL PURPOSES ONLY 

-

 DO NOT PRINT THIS PAGE IN MANUAL.

 

2

 

DESCRIPTION: MANUAL OWNER

S SERVICE FOR  MODEL 630 WHEELED EXTINGUISHER

 

3

 

ACTUAL PRINTED MATERIAL TO CONSIST OF ATTACHED

 

4

 

OVERALL SIZE OF PRINTED DOCUMENT PAGES  

8

-

1/2” 

11” 

ON 20 LB PAPER

 

5

 

PRINTED MATERIAL TO MATCH ATTACHED IN SADDLE STITCHED BOOKLET FORM

 

6

 

PRINT MATERIAL IS TO BE HOLE PUNCHED 3 EACH 

1/4” 

HOLES DOWN LEFT SIDE FOR STD 3

-

RING BINDER

 

7

 

CURENT REVISION DATE: 4/20

 

PART 

TITLE

 

DATE CREATED

 

CREATED BY

 

REV.

 

CK

D

 

 

05615

 

MANUAL SERVICE OWNERS 630

 

2/3/98

 

MS

 

 

G

 

 

THIS DRAWING IS THE EXCLUSIVE AND CONFIDENTIAL PROPERTY OF AMEREX 

CORPORATION.  IT SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS 

REV

 

DRAWING CHANGE

 

BY

 

ECN#

 

DATE

 

E

 

 

Update Manual in Publisher 

 

 

JH

 

B000772

 

 

8

-

6

-

15

 

F

 

 

Updated for 2.31 GL Charge

 

 

JH

 

B000961

 

 

2

-

15

-

16

 

 

G

 

 

REFRESHED LAYOUT DESIGN

 

CT

 

B002026

 

4/29/20

 

COVER SHEET

 

DO NOT PRINT THIS PAGE FOR ACTUAL MANUAL. INTERNAL USE ONLY.

 

Summary of Contents for 630

Page 1: ...ATERIAL IS TO BE HOLE PUNCHED 3 EACH 1 4 HOLES DOWN LEFT SIDE FOR STD 3 RING BINDER 7 CURENT REVISION DATE 4 20 PART TITLE DATE CREATED CREATED BY REV CK D 05615 MANUAL SERVICE OWNERS 630 2 3 98 MS G THIS DRAWING IS THE EXCLUSIVE AND CONFIDENTIAL PROPERTY OF AMEREX CORPORATION IT SHALL NOT BE DUPLICATED USED OR DISCLOSED TO OTHERS REV DRAWING CHANGE BY ECN DATE E Update Manual in Publisher JH B000...

Page 2: ...TELY AFTER ANY USE OWNER S SERVICE MANUAL INSTALLATION OPERATING SERVICING INSTRUCTIONS MANUAL PN 05615 33 GALLON FOAM WHEELED EXTINGUISHER MODEL 630 AMEREX CORPORATION P O BOX 81 TRUSSVILLE ALABAMA 35173 0081 Phone 205 655 3271 Fax 800 654 5980 e mail sales amerex fire com Web Page http www amerex fire com AMEREX CORPORATION DOES NOT SERVICE MAINTAIN OR RECHARGE FIRE EXTINGUISHERS THIS MANUAL IS ...

Page 3: ...LACING IT INTO SERVICE 1 Remove all wrappings straps and pallet retaining bolts 2 Examine the extinguisher for shipping damage Check to make sure that you have received the Model 534 2 gal AFFF foam concentrate charge that is packaged with the extinguisher 3 Fill the extinguisher by carefully following the Recharge instructions Page 6 4 Remove the nitrogen cylinder protective shipping cap Save the...

Page 4: ...on and in the proper fire fighting technique Familiarize all personnel with this information before an emergency occurs 1 Move the extinguisher to within approximately 50 feet 15 meters of the fire site and remove pull pin Pull T handle to open nitrogen valve This will pressurize the extinguisher 2 Remove nozzle from the mount and with the nozzle lever in the closed position pull hose from rack 3 ...

Page 5: ...NCE SERVICE PROCEDURE WARNING BEFORE SERVICING BE SURE THE EXTINGUISHER AGENT CYLINDER IS NOT PRESSURIZED THIS PROCEDURE IS BEST ACCOMPLISHED WITH THE EXTINGUISHER IN AN UPRIGHT POSITION AND ON A LEVEL SURFACE 1 Clean extinguisher to remove dirt grease or foreign material Check to make sure that the instruction nameplate is securely fastened and legible Inspect the cylinders for corrosion abrasion...

Page 6: ...h a stiff bristle nylon brush Remove the fill cap gasket and check for wear cracks or tears replace if necessary Lightly lubricate the gasket with V 711 and reinstall 10 Check the condition of the chemical solution The level of the solution shall be 9 inches 23 cm below the top of the fill opening Recharge if contaminated if the solution level is down or if the charge is over three years old See R...

Page 7: ...the Closed forward position into the nozzle mount 16 Remove the safety vent plug from the nitrogen cylinder Reconnect the high pressure hose securely to the nitrogen cylinder valve Wipe the extinguisher clean Record service data on the inspection tag according to NFPA 10 requirements and attach to extinguisher Return extinguisher to its proper location RECHARGE CAUTION THE FIRE EXTINGUISHING AGENT...

Page 8: ...SE A MALFUNCTION OR PREMATURE RUPTURE OF THE SAFETY DISC 6 Install an Amerex PN 03817 23 cu Ft nitrogen cylinder pressurized to 2015 psi Remove the shipping cap tighten the wing nuts securely and attach the nitrogen hose Remove the remainder of the ruptured moisture seal from the agent cylinder fitting Replace with a new PN 07411 Moisture Seal Assembly Carefully follow the installation instruction...

Page 9: ...rogen cylinders Valve seat has leaked and has pressurized the agent cylinder Follow Recharge Procedure for restoring the extinguisher to service 3 Nitrogen pressure is too low Valve is closed Tamper seal is intact No pressure observed in the agent cylinder Leakage in the nitrogen valve at other than the valve seal Replace with a properly charged nitrogen cylinder 4 Shutoff nozzle does not move fre...

Page 10: ... placing between side brackets and over the top bracket 2 The second loop is a REVERSE loop Notice that the hose passes behind the loop on this reverse loop If instructions are followed the hose will uncoil without kinks 3 The next loop is a regular hose in front loop Succeeding loops are alternated reverse front reverse etc for six full loops 4 Adjust the loops so that the nozzle fits into the no...

Reviews: