Page 7 American Access Systems / Security Brands, Inc.
FUNCTION CODE
DESCRIPTION
“Master Code”
This is a 5 digit programmable code between 00000
and 65535 used for gaining access to the program
mode. The factory default is “0 1 2 5 1”.
“Relay A Latch Card”
This is a user programmable card(s) used to lock
down (or unlock) relay A. This code will be used to
hold open a gate or door connected to relay A.
“Relay B Latch Card”
This is a user programmable card(s) used to lock
down (or unlock) relay B. This code will be used to
hold open a gate or door connected to relay B.
“Sleep Card”
This is a 5 digit programmable code between 00000
and 65535 used to put the unit to sleep. In the sleep
mode all codes are disabled with the exception of
the MANAGERS CODES. When the “SLEEPCODE” is
reentered again the unit will wake up.
“APB Code”
This is a 5 digit programmable code between 00000
and 65535 used to clear the antipassback status of
specific or all codes in memory
“Second Relay Card”
This is a 5 digit programmable code between 00000
and 65535 used to momentarily activate relay B. A
maximum of 5 codes may be assigned for the 24-
100 & 24-500, and a maximum of 10 codes for the
24-1000 & 24-2000.
“Managers Cards”
This is a 5 digit programmable code between
00000 and 65535 used to gain access onto the
property. This code will activate the appropriate
relay regardless of the sleep state of the unit. A
maximum of 15 codes may be assigned for the 24-
100 & 24-500, and a maximum of 30 codes for the
24-1000 & 24-2000
FUNCTION CODES
GOODBEEPS, ERRORBEEPS, & QUICKBEEPS
Your unit will beep each time a key is pressed. The “*” key serves as the clear key and a double beep will be heard
when this key is pressed. A “GOODBEEP” is represented by an oscillating high tone. An “ERRORBEEP” is represented
by a single low tone. A “QUICKBEEP” is a series of 5 quick high beeps in succession.
THE RED & YELLOW LED’s
Two different colored LED’s are mounted in the face of the unit. The RED LED will light during the duration of the
relay(s) activation period. The YELLOW LED will light while the unit is in the program mode. During memory clear or
setup both LED’s will flash
RESETTING THE UNIT
Your ADVANTAGE DKS II unit provides two different types of resets, a UNIT RESET, and a MASTER RESET. A MASTER RESET
should be utilized in the event that you lose or forget your master code or if the unit is locked in the sleep, lockA, or
lockB mode. When a MASTER RESET is performed, only the master code will be changed. A UNIT RESET is provided
should it ever become necessary to reset the unit back to the initial factory state. After a UNIT RESET has been
performed the unit will erase all ACCESS & FUNCTION codes from memory and the master code will be set back to
the factory default of 0 1 2 5 1.