3
Removable
Heat Recovery
Core
Drain Pan
Drain spout
FRONT
TOP
knockout for
side mounting of
EXHAUST return
port
6" round collar
converted to oval
minimum
18 inches (459 mm)
required for
service access
Threaded
inserts (4)
at corners
SUPPLY
Fresh air
from outside
5" round collar
SUPPLY
Fresh air
to building
6" round
(conv. to oval)
collar
EXHAUST
Stale Air
to outside
5" round collar
EXHAUST
Return air
from building
Choice of port location
Knockouts on top and
side of unit (use 1 only)
6" round (conv. to oval)
collar supplied
18.5"
(470 mm)
18.5"
(470 mm)
16"
(406 mm)
SIDE
Hanging
straps (4)
24.5"
(622
mm)
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
Model HRV95SRD
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed
for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of the cabinet designed to accept PVC
reinforced polyester straps that are supplied with the unit.
DEFROST
Recirculating defrost system.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to
prevent exterior condensation. Drain connections 2 - 1/2" (12 mm) OD.
WEIGHT
52 lbs. (23.6 kg)
SHIPPING WEIGHT
56 lbs. (25.4 kg)
PREMIUM SERIES ELECTRONICS
• Built-in Relay for Interfacing to furnace
• Built-in Dehumidistat disable feature
CONTROLS & ELECTRONICS
The
Premium Series Digital Control
(Model ADXC-II) is included with unit and can be wall
mounted in a central location of the home.
• 2 Speed Operation on each mode
• 4 user selectable operational modes: Continuous Ventilation, 20 ON/40 OFF,
20 ON/40 Recirculation, Continuous Recirculation
• Adjustable Dehumidistat function built into the main wall control
• Connected to 3 wire 20 gauge low voltage wire
OPTIONAL PROGRAMMABLE CONTROL
Premium Series Digital Control
(Model APVC) - contains all the features of the Premium Series
Digital Control with 5 speeds and 7/24 programmable ventilation, (3 wire) 20 gauge
wire (min.) 100' length
OPTIONAL TIMERS
DET-II
20/40/60 Minute Timer
- Initiates high speed ventilation for 20, 40, or 60
minutes, (3 wire) 20 gauge wire (min.) 100' length
28998
Mechanical Timer
- Initiates High speed ventilation for up to 60 minutes,
(2 wire) 20 gauge wire (min.) 100' length
OPTIONAL ACCESSORIES
DH-II
Dehumidistat
-
Initiates high speed ventilation when the indoor humidity level is
above the set point. (3 wire) 20 gauge wire (min.) 100' length
22025
Weatherhoods
,
Two - 5” (125 mm) c/w 1/4” (6 mm) mesh screen
ZRT-1 Zone Register Terminal
permits intermittent ventilation control at any exhaust terminal,
controlled by local timer switch, simultaneously turns HRV/ERV on high speed.
Suggested use: bathrooms and shower areas.
ZRT-2 Zone Register Terminal
permits constant low airflow with boost exhaust, controlled by
local timer switch, simultaneously turns HRV/ERV on high speed. Suggested use:
bathroom and shower areas.
Constant Exhaust Registers:
Airflows remain constant while other zones are turned on and
HRV/ERV runs at high speed. Suggested use: laundry areas and pet rooms.
WARRANTY
Units carry a fifteen (15) year warranty
on the heat recovery core and a two (2)
year replacement parts warranty.
All units conform to
CSA and UL standards.
*Sensible Efficiency – thermal **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance
(HVI certified)
Net supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure)
[cfm (L/s)]
@ 0.1" (25 Pa)
76 (36)
@ 0.2" (50 Pa)
73 (34)
@ 0.3" (75 Pa)
70 (33)
@ 0.4" (100 Pa)
66 (31)
@ 0.5" (125 Pa)
60 (29)
Max. Temperature Recovery
88%
Sensible Effectiveness
@ 60 cfm (28 L/s)
32°F (0°C)
88%
*Sensible Efficiency
@ 60 cfm (28 L/s)
32°F (0°C)
75%
*Sensible Efficiency
@ 61 cfm (29 L/s)
-13°F (-25°C)
68%
VAC @ 60HZ
120
WATTS / Low speed.
59
WATTS / High speed
89
Amp rating
0.9
Static Pressure (in w.g.)
A
ir
Flow
(c
fm
)
Speed 5
Speed 4
Speed 3
Speed 2
Speed 1
20
30
40
50
60
70
0
0.1
0.2
0.3
0.4
0.5
0.6
80
4 - Medium High Speed
3 - Medium Speed
2 - Medium Low Speed
1 - Low Speed
5 - High Speed
DIMENSIONS HRV95SRD
(