32
K6
K5
K7
K3
K4
P4
BLUE
P2
RED
K2
HIGH VOLTAGE
12V LOW VOLTAGE
LEGEND
P1
P3
GREEN
WHITE
BLACK
WHITE
Motors
Note: If any of the original
wire supplied with the unit
must be replaced, use only
TEW certified wire
IMPORTANT: Control low voltage is 12VAC
DO NOT CONNECT EXTERNAL POWER
SOURCES TO THE UNIT.
DEFROST DETAILS
P1
1 2
3
4
PIN 1 - RED
PIN 2 - ORANGE
PIN 3 - BLACK
PIN 4 - SPARE
PCB PLUG - IN
RED
BLACK
PLUG IN
BI-DIRECTIONAL
ORANGE
RED
BLACK
ORANGE
CONNECTOR
DAMPER MOTOR
59-TPD-W
AUTO-TRANSFORMER DETAIL
PINS 1, 2 AND 3 ARE OPTIONAL
3
2
2
1
1
5
6
4
P3
P6
P3
PIN 1 - BLUE
PIN 4 - RED
PIN 2 - YELLOW PIN 5 - WHITE
PIN 3 - BROWN PIN 6 - BLACK
P6
PIN 1 - GREEN
PIN 2 - GREEN
PLUG IN CONNECTOR
AUTO
TRANSFORMER
AUTO-
TRANSFORMER
BLACK
WHITE
Model RNC5 (Only)
SEE
DEFROST
DETAIL
ON
LOW
RED
YEL
GRN
HI
COM
NO
NC
BLK
Thermistor
(Not on all units)
Residential Wiring Diagram
Model HRV120SRD