02Er – TILT movement error:
If the head is not located in the default tilt position after start-
up or after a reset command. This message will appear after a
fixture reset, if the tilt magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or a defective motor IC drive on the
main PCB).
Accu Fog 1000
error Codes
Accu Fog 1000
error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will flash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “02Er,” it means there is some type
of error with the channel 2 motor. If there are multiple errors
during the start-up process they will all flash in the display. For
example: if the fixtures has errors on channel 1 and channel 2
at the same time, you will see the error message flash “01Er”
and “02Er” repeated 5 times.
If an error does occur during the initial start-up procedure the
fixture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
fixture will make the following determinations:
1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the fixture has less than 3 errors, there
-
fore most other functions will work properly. The fixture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
If the yoke is not located in the default position after start-up or
after a reset command. This message will appear after a fixture
reset, if the pan-yoke’s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or a defective motor IC drive on the
main PCB).