TYPE 1
DATA IN
XLR MALE SOCKET
3 Data -
Data+ 2
1 Ground
TYPE 2
DATA IN
XLR MALE SOCKET
3 Data +
Data - 2
1 Ground
Addressing Fixtures
In order to have individual control of each fixture with
the DMX operator Fixture addresses should be addressed
as follows.
Scanner Button # 1 starts at 1
Scanner Button # 2 starts at 17
Scanner Button # 3 starts at 33
Scanner Button # 4 starts at 49
Scanner Button # 5 starts at 65
Scanner Button # 6 starts at 81
Scanner Button # 7 starts at 97
Scanner Button # 8 starts at 113
Scanner Button # 9 starts at 129
Scanner Button # 10 starts at 145
Scanner Button # 11 starts at 161
Scanner Button # 12 starts at 177
If you are not sure how to set the starting address of your
Fixture refer to Chart on pages 20 & 21 of manual.
American DJ Los Angeles, CA 90058 -
DMX OPERATOR