American DJ
®
- www.americandj.com - Vizi LED Spot - Instruction Manual - Page 26
American DJ
®
- www.americandj.com - Vizi LED Spot - Instruction Manual - Page 25
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
FLIP
-
This function will reverse the display 180º.
1. Access the main menu.
2. Tap the UP button until “
DISP
” is displayed.
3. Tap the UP button until “
FLIP
” is displayed, press ENTER.
4. Press the UP or DOWN buttons to select either “
ON
” to acti-
vate this function, or “
OFF
” to deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
LOCK
-
With this function you can activate the automatic
button lock. When this function is activated, the buttons
will automatically lock 15 seconds after the last press of
a button. In order to deactivate the button lock, press the
MODE/ESC button for 3 seconds.
1. Access the main menu.
2. Tap the UP button until “
DISP
” is displayed.
3. Tap the UP button until “
LOCK
” is displayed, press ENTER.
4. Press the UP or DOWN buttons to select either “
ON
” to acti-
vate this function, or “
OFF
” to deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
SPEC
MAIN MENU -
RDMX
With this function you are able to change the DMX
address via any DMX controller. This function is factory set
Vizi LED Spot
System Menu
to “ON” already.
1. Access the main menu by pressing MODE/ESC.
2. Tap the UP button until “
SPEC
” is displayed, press ENTER.
3. Tap the UP button until “
RDNX
” is displayed, press ENTER.
4. Press the UP button to select “
ON
” to activate this function,
or “
OFF
” to deactivate.
5. Press ENTER to confirm, and “
PASS
” will flash quickly.
6. Press MODE/ESC to return to the main menu.
To use this function follow the instructions:
To adjust the address of your unit you must first go to the
address that it is currently set to. From there you can adjust the
address. First make sure all channels are set to the value of “0”.
1. On your DMX controller set the DMX value of Channel 1 to
the value “7”.
2. Now set the DMX value of Channel 2 to the value “7” to
adjust the starting address between 1 and 255. To adjust the
address between 256 and 511 set Channel 2 to the value “8” .
3. Set the DMX value of Channel 3 to your desired start-
ing address. This will take about 20 seconds before the unit
accepts the new DMX address.
EXAMPLE:
So, if you want the address to be 57, you must first
set the address that is currently assingned to the unit. The pro-
ceed to set Channel 1s’ value to “7”, Channel 2s’ value to “7”,
and Channel 3s’ value to “57”.
2ND EXAMPLE:
Again, if you want the address to be 420, you
must first set the address that is currently assingned to the unit.
If you want the set the address to 420, set Channel 1s’ value to
“7”, Channel 2s’ value to “8”, and Channel 3s to “164”. (256 +
164 = 420)
SPOT
- With this function you can adjust the LED via
Vizi LED Spot
System Menu