2. Technical Gas Data
a. Gas Specifications
b. Gas Connections
Inlet connection ---- 1-inch N.P.T.
Inlet supply size ---- 1-inch N.P.T. (minimum)
Btu/hr input--------- 270,000 (68,040 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryers gas valves internal regulator. Incoming supply pressure
must be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12 inches
water column (29.9 mb) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valves internal pressure regulator blocked open so
that the gas pressure
must be
regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap
must be
a consistent 10.5 inches water column (26.1 mb). There is no regulator
or regulation provided in an L.P. dryer. The water column pressure
must be
regulated at the source
(L.P. tank) or an external regulator
must be
added to each dryer.
* D.M.S. (Drill Material Size) equivalents are as follows:
Natural Gas ........................... #23 = .154 (3.9116 mm)
Liquid Propane Gas .............. #41 = .096 (2.4384 mm)
T
YPE OF
G
AS
Natural
Liquid Propane
Manifold Pressure*
3.5 inches W.C.
8.7 mb
10.5 inches W.C.
26.1 mb
Inline Pressure
6.0 - 12.0 inches W.C.
14.92 - 29.9 mb
10.5 inches W.C.
26.1 mb
Shaded areas are stated in metric equivalents
* Measured at gas valve pressure tap when the gas valve is on.
T
YPE OF
G
AS
L.P.
Conversion Kit
Part
Number
MODEL
NUMBER
BTU
Per Hour
Rating
kcal/hr
Rating
Natural
Liquid Propane
Qty. D.M.S.*
Part
Number
Qty. D.M.S.*
Part
Number
MLG-82
270,000
68,040
4
#23
140856
4
#41
140811
882119
Shaded area is stated in metric equivalent