33
5. Make a complete operational check of
ALL
safety related circuits:
a. Door Switch(es)
b. Hi-Limit thermostats
c. Sail switch (for Gas Models Only)
NOTE:
To check for proper sail switch operation (for Gas Models Only), open the main door and
while holding main door switch plunger in, start dryer. Dryer should start but heat circuit
should not be
activated (on). If the heat system is activated, the sail switch is improperly
adjusted and
must be
adjusted by bending the actuator arm of the sail switch toward the
burner box. If the actuator arm is bent too far toward the burner box of the dryer, the dryer
may not have heat when needed. After any adjustment to the sail switch, the above procedure
must be
repeated to verify proper operation of the sail switch.
6. The dryer
should be
operated through one (1) complete cycle to assure that no further adjustments are
necessary and that
ALL
components are functioning properly.
BASKET COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material
with a solution of water and non-flammable mild detergent and tumbling them in the basket (tumbler) to remove
this coating.
7. Make a complete operational check of
ALL
operating controls.
a. For microprocessor model check controller (computer) programs/selections...
1) Each microprocessor controller (computer) has been preprogrammed by the factory with the most
commonly used parameter (program) selections. If computer program changes are required, refer
to the computer programming manual which was shipped with the dryer.
8. Check the electric service phase sequence (three-phase [3ø] models only). While the dryer is operating,
check to see if the blower wheel (impellor/fan) is rotating in the proper direction. Looking from the front,
the blower wheel (impellor/fan) should spin in the clockwise (CW) direction. If it is, the phasing is correct.
If the phasing is incorrect, reverse two (2) of the three (3) leads at connections L1, L2, L3 of the power
supply to the dryer.
IMPORTANT:
If the blower wheel (impellor/fan) is rotating in the wrong direction, this
will
not
only
drastically reduce drying efficiency, but it can also cause premature component failure.