34
9. REVERSING MODELS ONLY - basket (tumbler) dryer
should never be
operated with less than a 30
lb. (13.7 kg) load (dry weight). The size of the load will affect the
coast-down and dwell (stop) times. The basket (tumbler)
must come
to a complete stop before starting in opposite direction.
a. Microprocessor Models
1) Spin and stop are not adjustable in the Automatic Mode and have been preprogrammed into the
microprocessor controller (computer) for 150-seconds spin time in forward direction, 120-seconds
in the reverse direction and a 5-second dwell (stop) time.
2) Spin and stop times are adjustable in the Manual (timed) Mode.
10. Check to insure that
ALL
set screws (i.e., tumbler drive, idler, etc.) are tight.
K. PREOPERATIONAL INSTRUCTIONS
1. To start the dryer:
a. Microprocessor (computer) dryers
1) The L.E.D. (light emitting diode) display will read REAdY.
2) Press the E on the touchpad of the keyboard.
3) The dryer will start and the display will flash dRYING MANUAL CYCLE E dRY TEMP 180F
COOL TEMP 80F 30 REMAIN dRUM TEMP
Refer to the Users Manual for detailed operating instructions.
L. SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following
must be
performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a.
GAS MODELS
... discontinue the gas supply
.
1)
SHUT OFF external gas supply shut-off valve
.
b.
STEAM MODELS
... discontinue the steam supply
.
1)
SHUT OFF external (location furnished) shut-off valve
.
2)
SHUT OFF external steam valves in the supply lines and the return lines
.
All manuals and user guides at all-guides.com