40
C. LUBRICATION
1. The motor bearings, idler bearings ... and under normal/most conditions the tumbler bearings are permanently
lubricated. It is physically possible to relubricate the tumbler bearings if you choose to do so, even though
this practice is not necessary. Use Shell Alvania #2 grease or its equivalent. The tumbler bearings used in
the dryer does not have a grease fitting. Provisions are made in the bearing housing for the addition of a
grease fitting which can be obtained elsewhere, or from
ADC
by ordering kit Part No. 882159 (which
includes two [2] fittings).
2. Impellor (fan) shaft bearings
must be
lubricated
every three (3) months.
Use Shell Alvania #2 grease or
its equivalent.
D. LINT DRAWER REMOVAL
To remove the lint drawer from the dryer pull drawer out approximately half way. Rotate and move lint drawer
stop hinge (refer to the
illustration
below) downward and pull drawer out.
IMPORTANT:
After reinstalling the lint drawer back into the dryer, be sure to rotate/move the hinge
back to the upward stop position.