I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR PHASE 6 MODELS
(STEAM MODELS ONLY)
This dryer was manufactured with a manual reset tumbler/lint chamber hi-limit thermostat which is monitored by
the Phase 6 computer. If the manual reset thermostat is open prior to start of the drying cycle, the dryer will start
momentarily and then shut down, displaying dRUM SAFETY FAIL with an audio indication.
If the manual reset hi-limit thermostat opens during a drying cycle, the display will read dRUM SAFETY FAIL
with an audio indication. If the drum temperature is above 100º F (38º C), the dryer will continue to run with no
heat for three (3) minutes or until the drum temperature has flattened below 100º F (38º C). The clear/stop button
on the Phase 6 keyboard (touchpad)
must be
pressed to clear this dRUM SAFETY FAIL condition. The open
manual reset hi-limit thermostat
must be
reset manually prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner operation.
The tumbler manual reset hi-limit is locked in the chamber area.
WARNING:
Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a lint
chamber hi-limit thermostat which
must
be
reset manually.
WARNING:
Discontinue power to dryer
before attempting to reset hi-limit.