14
NOTE
: When fire sprinkler systems are located above the dryers, a minimum of 18-inches (45.72 cm)
above the dryer console (module) is required. Dryers may be positioned sidewall to sidewall,
however, 1 or 2-inches (2.54 or 5.08 cm) is suggested for ease of installation and
maintenance. Allowances
must be
made for the opening and closings of the control door and
the lint door.
C. DRYER ENCLOSURE REQUIREMENTS
Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be
positioned approximately 2 feet (24-inches) from the nearest obstruction (i.e., wall) for ease of installation,
maintenance, and service. Bulkheads and partitions
should be
made from noncombustible materials. The
clearance between the bulkhead header and the dryer
must be
a minimum of 4-inches (10.16 cm) and must not
extend more than 4-inches (10.16 cm) to the rear of the front. A 2-inch (5.08 cm) clearance is required between
the bulkhead facing and the top of the dryer.
NOTE
: Bulkhead facing
should not
be
installed until after the dryer is in place. Ceiling area
must be
located a minimum of 12-inches (30.48 cm) above the dryer top console (module) and
18-inches (45.72 cm) for steam models.