19
a. Gas and Steam Models Only
* AWG Stranded Wire Type - size wire as per National Electrical Code or local codes.
** 3-Wire available.
5/26/05
* AWG Stranded Wire Type - size wire as per National Electrical Code or local codes.
** 3-Wire available.
5/26/05
b. Electric Models Only
ALL
electrically heated dryers
must
be
connected to the electric service shown on the dryer’s data
label. The connecting wires
must be
properly sized to handle the rated current.
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz
50 Hz
30 kW
208
3ø
3
91
—
*
125
125
230
3ø
3
—
83
*
125
125
240
3ø
3
79
—
*
100
100
380
3ø
3
48
—
*
60
60
380
3ø
4**
—
54
*
70
70
400
3ø
4**
—
51
*
70
70
416
3ø
4**
—
50
*
70
70
460
3ø
3
40
—
*
50
50
480
3ø
3
39
—
*
50
50
575
3ø
3
33
—
*
50
50
36 kW
208
3ø
3
108
—
*
150
150
230
3ø
3
—
98
*
125
125
240
3ø
3
94
—
*
125
125
380
3ø
3
58
—
*
80
80
380
3ø
4**
—
63
*
80
80
400
3ø
4**
—
60
*
80
80
416
3ø
4**
—
58
*
80
80
460
3ø
3
48
—
*
60
60
480
3ø
3
46
—
*
60
60
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz
50 Hz
120
1ø
2
13.0
—
*
20
20
208
1ø
2
7.6
—
*
15
15
220
1ø
2
7.3
8.6
*
15
15
230
1ø
2
—
8.0
*
15
15
240
1ø
2
7.0
—
*
15
15
208
3ø
3
4.7
—
*
15
15
230
3ø
3
—
4.7
*
15
15
240
3ø
3
4.9
—
*
15
15
380
3ø
3
2.9
—
*
15
15
380
3ø
4**
—
3.1
*
15
15
400
3ø
4**
—
3.2
*
15
15
416
3ø
4**
—
3.1
*
15
15
460/480
3ø
3
2.8
—
*
15
15